APPENDIX
A
POWER AND ECU HARNESS MAINTENANCE
1. Disconnect the ECU harness connector and inspect for signs of moisture or corrosion.
2. If moisture of corrosion is detected, use Deoxit D5, brushes, and compressed air to clean and dry the
connector.
3. When clean, apply a coating of Corrosion X HD to the connector mating surfaces and contacts.
4. Reattach the connectors.
HAWKEYE® 2 BOOM HARNESS CONNECTOR MAINTENANCE
NOTE:
The electrical connection of the Hawkeye® 2 NCVs should come with CorrosionX HD pre-applied and
protected with a dust cap. Verify the pins are coated adequately with CorrosionX HD when removing
the dust caps from the NCV.
Prior to connecting the Hawkeye® 2 boom cable to the Nozzle Control Valves (NCV), perform the following steps
to all 8-pin NCV connectors and 19-pin circular connectors between the boom cables and RCM - Sprayer cable
connections to ensure high quality connections:
1. Verify the NCV connectors and the accompanying boom cable connectors are free of moisture, contamination,
or oxidation. Oxidation will appear as a dry, white coating on the contacts. If any connectors show signs of
moisture, contamination, or oxidation, perform Step 2 - Step 6. If this is a new installation, skip to Step 7. All
components listed below can be ordered in the Hawkeye® 2 NCV Connection Maintenance Kit (P/N 117-0171-
692).
Cable and Connector Maintenance: Power and ECU Harness Maintenance