Replacing The T-Sensor (Ke-2080R) - JUKI KE-1070 Maintenance Manual

High-speed chip scooter
Table of Contents

Advertisement

2-4. Replacing the T-Sensor (KE-2080R)

After the T-sensor has been replaced, perform the home position return to check that it functions
correctly.
(For details about input items, see section 2-9.)
(1) Detach the T-sensor bracket from the head.
(2) Remove the mounting screws
(3) Cut the tie-up band securing the T-sensor cables.
(4) Remove the T-sensor
(5) Reassemble the components in the reverse order of disassembly.
(6) Check following the procedure below and make adjustments if necessary.
<Procedure>
Make the adjustment so that the clearance between the T-sensor
2 mm or less and that the T-sensor is not in contact with other part around it, such as
pulley.
Manually rotate the -axis to make sure that the T-sensor is not in contact with the
T-sensor dog.
Put the servo in the free status with the power to the machine turned ON and manually
rotate the -axis to make sure that the sensor is turned ON or OFF if the sensor gets close
to the dog.
Maintenance Guide
(2 pcs.) of the T-sensor bracket
from the bracket and replace it.
Figure 2-4-1
2-14
and detach the bracket.
and T-sensor dog
is

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-1070cKe-2070cKe-2070Ke-1080Ke-2080Ke-2080r

Table of Contents