1-9-3. Assembling the Cable
(1) Apply the grease to portions where the 40058385, 40044517, 40044543, and 40080206
cables are put in the plastic rail, and place the cables and air tubes in the X-axis plastic rail
as shown in the figure below (figure viewed from A).
Check the connector orientation and take care so that the air tubes do not become warped.
Viewed from A
(2) After the cables and air tubes have been run correctly, put the cover of the plastic rail.
Maintenance Guide
Figure 1-9-3-1
XY veyor-cable
Figure 1-9-3-2
1-41
Viewed from A
X plastic rail