Panasonic A230 User Manual page 78

Machine vision system

Advertisement

Environment and Product Type
5.2
Environment Settings (Environment settings common for all types)
5.2.5
Communication
Set serial, parallel or other communications.
[5] ENVIRONMENT
4.
Communication
41. Com. Mode
42. RS232C
43. Serial Output
44. Perallel Output
45. Type Switch Min.
41. Communications Mode
Select either Normal Mode or Computer Link as the communications mode.
42. RS232C
43. Serial Output
44. Parallel Output
45. Type Switch Min. (0 to 100ms, 10ms units)
Set the minimum type switch time for switching using parallel or serial
input.
Because the type switch time is extremely short, this function can prove
effective in cases when it is not possible to perform switch completion
notification using the external device. The initial setting is 0ms.
Example:
1) Setting value = 0ms: READY signal OFF time = switch time
2) Setting value
3) Setting value
Ex.
5 − 8
Normal Mode
0 ms
Refer to 16. Communications
(Serial/Parallel) for detals.
switch time: READY signal OFF time = switch time
>
switch time: READY signal OFF time = setting value
Setting value
1
0ms
2
10ms
3
50ms
Switch time
20ms
20ms
>
20ms
OCR Type A230
READY signal OFF time
20ms
20ms
50ms