Download Print this page

Panasonic A230 User Manual page 293

Machine vision system

Advertisement

OCR Type A230
Data
Transmission Function
C
%Z
External device
R
to A230
C
%U
External device
R
to A230
C
%Q
(*1)
External device
R
to A230
C
%Q
External device
R
to A230
*1: This command can be invoked even when menus other than the main menu, such as the Numerical
Calc., Output, and Spreadsheets menus are displayed.
Notes
Perform serial communications using the main menu with
READY in the on state.
Transmission of data at speeds of 19,200bps or greater is not
supported by some hardware and/or software, and may not
work correctly. Be certain to test the transmission under
actual operating conditions before use.
Note that serial input is not complete until the
terminator byte arrives.
If a command is ignored even though it is correct, send the
terminator byte (
Switching product types may take some time.
16.3 Serial/Parallel Communication Command Tables
Data not registered error
command
Data code error command Output when an undefined command is trans-
Spreadsheets data reset
command
Spreadsheets data reset
answer command
C
(0dh)), and then input the command again.
R
Communications (Serial and Parallel)
Notes
Outputs if the type number, the register number or
the checker number in the command input is not
registered yet. Also outputs if camera switching
could not be executed.
mitted, or an illegal setting is specified for the
product type, a numerical operator, or checker No.
(e.g. %D, %F50, %O17 etc.).
Clears spreadsheet scanning and error counts,
averages, dispersions, maximum and minimum
values, and ranges.
Output after spreadsheet reset has completed.
C
(0dh)
R
16 − 17

Advertisement

loading