13.3
Numerical Calculation
Data Bit
Sets the data length for when you will output numerical calculation results using
parallel output. Select 8, 16 or 32 bits in accordance with the range of numerical
values that you will output. However, it is only possible to set one data length for
the four registers that are displayed at one time (e.g. if CA01 to CA04 are displayed,
it is not possible to set CA01 to 8 bits and CA02 to 16 bits).
The ranges that can be handled by the different data−bit sizes are as follows:
8−bit: 0 to 255
16−bit: 0 to 65535
32−bit: –2147483648 to 2147483647.
External output registers that are not set are skipped during output.
Output data length
8−bit data
d8 d1
16−bit data
d16
d1
32−bit data
d32
Data and operators that can be referenced
Refer to 13.3.4 Symbols used by Numerical Calculation Programs
for the various checker items that can be used in calculations.
Operators and symbols that can be used for calculations are as follows:
Addition: +
Subtraction: –
Multiplication: *
Division: /
13 − 8
(output pin No.)
(output pin No.)
(output pin No.)
d1
Left parenthesis: (
Right parenthesis: )
Atan: @
Root: $
Distance: T
Output port (output pin No.)
D8 D7
D6 D5 D4 D3 D2 D1
d8
d7
d6
d5
d4
d3
d2
D8 D7 D6 D5 D4 D3 D2 D1
d8
d7
d6
d5
d4
d3
d2
d16
d15
d14
d13
d12
d11
d10
D8 D7 D6 D5 D4 D3 D2 D1
d8
d7
d6
d5
d4
d3
d2
d16
d15
d14
d13
d12
d11
d10
d24
d23
d22
d21
d20
d19
d18
d32
d31
d30
d29
d28
d27
d26
OCR Type A230
d1
d1
d9
d1
d9
d17
d25

Advertisement

loading