OCR Type A230
Adjustment position (Re−registration Area Display: No)
Procedure:
1.
Specify the template number for performing re−registration, and input template
re−registration input signal IN8.
2.
READY signal goes off, and the position adjustment checker registered for the
position adjustment group No. of the specified smart matching checker is
executed, and the smart matching is adjusted.
3.
Re−registration is executed at the position of the smart matching that was
adjusted in step 2., and the positional relationship between the first registered
search area and the template is maintained.
4.
When re−registration is complete, the READY signal goes on.
Adjustment position (Re−registration Area Display: Yes)
Procedure:
1.
Specify the template number for performing re−registration, and input template
re−registration input signal IN8.
2.
READY signal goes off, and the position adjustment checker registered for the
position adjustment group No. of the specified smart matching checker is
executed, and the smart matching is adjusted.
3.
Re−registration is executed at the position of the smart matching that was
adjusted in step 2., and the template position (whose positional relationship
with the first registered search area has been maintained) is displayed as the
re−registration area.
4.
Input template re−registration input signal IN8 again.
5.
Re−registration is executed at the position of step 3., and when it is complete,
the READY signal goes on.
Notes
Templates other than those of the current type cannot be
re−registered.
Perform re−registration when the main screen READY signal
is in the on state.
The template is registered as a gray image, regardless of the
image displayed on the monitor.
Registration is possible if you capture a new image when the
monitor display image is a "Thru" image, but if it is a "Mem"
image, re−registration is executed using the currently
displayed image.
The re−registered template will be lost if the power is switched
off. If you wish to keep it, perform a data save before
switching the power off.