Download Print this page

Panasonic A230 User Manual page 182

Machine vision system

Advertisement

Smart Matching
9.1
Smart Matching
Detection results (Result)
− Number (Cnt.)
Shows the results of the search based on sequence, that is, the number
of objects detected in each step.
− Correlation (Cor.)
Shows the correlation values of objects detected in each step.
Rotation settings
− Angle range (Angle)
After an object has been detected based on the correlation value, the
Imagechecker rotates the template within the angle range set in the
rotation settings (±30), and detects the object's rotation angle.
− Accuracy (Acc.)
Set the minimum unit for rotating the template when performing angle
detection. Use the cursor lever to select the angle (to one decimal place).
The Imagechecker rotates the template at each angle set here, compares
it to the object, and finally detects the rotation angle.
9 − 6