2-32
General Description
CPU#1
Status
Status
Status
LED1
LED2
LED1
Off
Amber
Off
Off
Red
Green
Red
Off
Red
Green
Red
Off
Red
Amber
Red
Amber
Off
Amber
Off
Off
When the status LED 1 is off, the colors of the status LED 2 indicate the following. You
Tips:
must be careful especially when detaching modules.
- Green: Unmounting the module has no effect on the system operation.
- Amber: Unmounting the module cause a system down.
CPU#2
Status
LED2
Off
Off
AC power is not
supplied to the CPU
module 2.
The CPU module 1
operates in simplex
mode.
Red
Green
AC power is not
supplied to the CPU
module 1.
The CPU module 2 is
performing diagnosis
(Diag).
Off
Off
AC power is not
supplied to the CPU
module 2.
The CPU module 1 is
performing diagnosis
(Diag).
Red
Off
On standby (AC power
is supplied through the
cord, but the system
has not been powered
on yet.)
Red
Off
The CPU module 1 is
performing diagnosis
(Diag).
Red
Green The CPU module 2 is
performing diagnosis
(Diag).
Off
Amber
The CPU module 1
memory is being
Off
Off
dumped. (This occurs
only when
maintenance is being
performed.)
Red
Amber
The CPU module 2
memory is being
Red
Amber
dumped. (This occurs
only when
maintenance is being
performed.)
Description
Check if the power cord is
connected correctly.
Check the condition of breaker
and UPS.
Check if the power unit is
connected correctly.
Remount the CPU module 2.
If the problem persists, contact
your sales agent.
Wait for the OS to start. After the
OS starts, check the status LEDs
and then take the appropriate
actions.
If the problem persists, contact
your sales agent.
After turning on the power, wait for
the OS to start.
When the OS starts and duplex
mode is established, the
indications will return to normal. If
not, check the status LEDs and
then take the appropriate actions.
If the problem persists, contact
your sales agent.
-
-
Action