NEC Express 5800/320Lc User Manual page 173

Nec server user's guide
Table of Contents

Advertisement

TIPS:
A message informing you of the completion of CMOS clear and prompting you to
clear CMOS will appear for 10 seconds. Note that even if you do not do anything,
the process goes on and the server will be rebooted automatically.
8.
If the message [Non volatile memory cleared] appears after rebooting and during POST,
turn off the power by pressing the POWER switch and unplug the both power cords.
IMPORTANT:
If the message [Non volatile memory cleared] appears at normal startup, the jumper
switch is set for clearing CMOS. Change back the jumper switch setting.
9.
Remove the PCI Module #1 from NEC Express5800/ft series (see "Removing PCI
Module" on page 8-29).
10.
Reset the jumper switch setting.
Remove the clips from the jumper pins 1-2 and place them on the jumper pins 11-12 on
the PCI Module #1.
TIPS:
If you place clips on other pins, the server may malfunction.
11.
Mount the PCI Module #1 again to NEC Express5800/ft series (see "Installing PCI
Module" on page 8-31) and plug the power cord to the AC inlet B (for Group1).
12.
Likewise, mount the PCI Module #2 to NEC Express5800/ft series and plug the power
cord to the AC inlet A (for Group2).
Non volatile memory cleared:
This message indicates that CMOS is cleared properly.
System Configuration
4-41

Advertisement

Table of Contents
loading

Table of Contents