NEC Express 5800/320Lc User Manual page 275

Nec server user's guide
Table of Contents

Advertisement

STATUS LED
Indication
Color State
Cor1 -12vAlm 07 Amber Blink PCI module #2
Cor1 -12vAlm 09 Amber
Cor1 Bus PERR
Green Blink PCI module #2
01
Cor1 Bus SERR
Green Blink PCI module #2
01
Cor1 CLK Alm 00 Amber Blink CLOCK board
Cor1 CLK Alm 02 Amber
Cor1 CLK Alm 07 Amber Blink CLOCK board
Cor1 CLK Alm 09 Amber
Cor1 FAN Alm 01 Amber Blink PCI module #2
Cor1 FAN Alm 02 Amber Blink PCI module #2
Cor1 FAN Alm 03 Amber Blink PCI module #2
Cor1 FAN Alm 04 Amber Blink PCI module #2
Cor1 FAN Alm 05 Amber Blink PCI module #2
Cor1 offline
Green Blink PCI module #2
Cor1 removed
Green Blink PCI module #2
Cor1 Temp Alm
Amber Blink PCI module #2
00
Cor1 Temp Alm
Amber
02
Cor1 Temp Alm
Amber Blink PCI module #2
07
Cor1 Temp Alm
Amber
09
CPU IERR 00
Green Blink CPU module #1
CPU IERR 01
Green Blink CPU module #1
CPU IERR 20
Green Blink CPU module #2
CPU IERR 21
Green Blink CPU module #2
CPU T-Trip 00
Green Blink CPU module #1
CPU T-Trip 01
Green Blink CPU module #1
CPU T-Trip 20
Green Blink CPU module #2
CPU T-Trip 21
Green Blink CPU module #2
CPU0 +12ss Alm
Amber Blink CPU module #1
00
CPU0 +12ss Alm
Amber
02
Suspected
module
Lit
PCI module #2
Lit
CLOCK board
Lit
CLOCK board
Lit
PCI module #2
Lit
PCI module #2
Lit
CPU module #1
Explanation
-12-V power voltage alarm
(upper limit)
Fatal -12-V power voltage
alarm (upper limit)
PCI bus parity error
Fatal PCI bus error
Clock alarm (lower limit)
Fatal Clock alarm (lower
limit)
Clock alarm (upper limit)
Fatal Clock alarm (upper
limit)
Cooling fan1 alarm
Cooling fan2 alarm
Cooling fan3 alarm
Cooling fan4 alarm
Cooling fan5 alarm
PCI module logically isolated
PCI module detached
Temperature alarm (lower
limit)
Fatal temperature alarm
(lower limit)
Temperature alarm (upper
limit)
Fatal temperature alarm
(upper limit)
CPU#1 internal error
CPU#2 internal error
CPU#1 internal error
CPU#2 internal error
CPU#1 thermal change error
(upper limit)
CPU#2 thermal change error
(upper limit)
CPU#1 thermal change error
(upper limit)
CPU#2 thermal change error
(upper limit)
+12-V power voltage alarm
(lower limit)
Fatal +12-V power voltage
alarm (lower limit)
Troubleshooting
7-7
Procedure
Contact your sales agent.
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
Start the PCI module by ft
sever utility or dismount
and remount that module.
If not solved by the above,
contact your sales agent.
Dismount and remount the
PCI module. If not solved
by the above, contact your
sales agent.
Check to see if dust is
accumulated on the
internal fans. Check also if
the fan cables are
connected securely. If not
solved by the above,
contact your sales agent.
Contact your sales agent.

Advertisement

Table of Contents
loading