3-42
Windows Setup and Operation
IMPORTANT:
10/100 Enet Adapter". Only Fault Tolerance mode can be selected.
6.
Click [OK].
The [Intel(R)PROSet II] dialog box closes after a while, and the settings become effective.
IMPORTANT:
The [Digital signature not found] dialog box may appear (several times). If it
appears, click [Yes].
After the settings of dual configuration, "Intel(R) Advanced Network Services
Virtual Adapter" will appear on the [Network and dialup connection] or [Device
Manager] dialog box. Therefore 6 adapters that consist of two "Virtual", two
"100Base", and two "1000Base" adapters will appear on the [Network and dialup
connection] or [Device Manager] dialog box. Do not "disable" the status of this
"Virtual Adapter". If you enable it again, the system may become unstable and you
may need to restart it.
Set IP address for "Virtual Adapter" after the settings of dual configuration. Do not
set IP address for "100Base Adapter" or "1000Base Adapter".
Use a hub for dual configuration. Use a repeater hub or a switching hub for AFT
function. Use a switching hub for ALB function.
Connect the network cables to the both primary and secondary PCI modules. After
the settings of dual configuration, if one network cable is disconnected from a PCI
module or a hub, the status of the PCI modules becomes simplex. In such case, if the
network cable is connected to the PCI module or the hub again, the status of the PCI
modules becomes duplex.
Load Balancing mode cannot be selected on "Stratus emb-82559