8-48
System Upgrade
2.
Build a dual LAN configuration. (See "Setting Dual LAN Configuration" in the separate
volume "User's Guide (Setup).")
IMPORTANT:
You can also select [Load Balancing] in step 3 in "Setting Dual LAN Configuration". In
this case, [Team #1:Adaptive Load Balancing Mode] is added to Network Component
Tree.
Moreover, select [Stratus AA-U5700 Fiber Gigabit Server Adapter] instead of [Stratus
emb-82559 10/100 Enet Adapter] in Steps 4 and 5.
PCI Board Status LED Indications
LED
Description
indications
Amber
Duplex is specified,
however, the server works
in simplex mode.
Off
PCI board is properly
installed and operates in
non-duplex mode (AFT,
ALB). (Does not depend on
simplex or duplex.)
PCI board is installed to
operate in the duplex mode.
The PCI board is not
installed yet, the PCI board
is installed incorrectly, or the
power is not supplied.
Red
In the process of configuring
or canceling the duplex
mode.
Although the PCI board is
mounted, it may be offline
or not be working.
Action
Specify duplex (AFT, ALB).
Specify an appropriate driver.
In non-duplex mode, no special problem
occurs.
The system is operating normally in duplex
mode.
Mount the PCI board correctly.
If the PCI board was not mounted, there is no
problem.
Check the condition of power unit.
Remount the PCI module.
Wait for a while until the indication changes. If
the indication unchanged, check the PCI board
slot status using NEC ESMPRO Manager.
Make the slot of the board installed from NEC
ESMPRO Manager online.
Mount the PCI board correctly.