3-50
Windows Setup and Operation
When you stop the operation of a CPU module, the indications of the status LEDs change as
follows. Below denotes that the only one CPU module is operating.
[Indications of status LEDs]
1
CPU module status LED1
2
CPU module status LED2
* As an example, the indications of when CPU module#1 is stopped are shown.
3.
Press the start button of the CPU module stopped by ft server utility.
In the ft server utility, select the stopped CPU module and click [Up] of [Bring Up/Bring
Down].
Once the CPU module is started, hardware diagnosis and then synchronization of memory
(memory copy) are performed, and the duplication process is completed.
Note that the system is paused temporarily for copying memory during memory
synchronization.
[Indications of status LEDs during diagnosis]
1
CPU module status LED1
2
CPU module status LED2
[Indications of status LEDs after completion of duplication]
1
CPU module status LED1
2
CPU module status LED2
IMPORTANT:
After duplication is completed, the status of memory will be checked.
Wait until this process ends to perform the next step (evaluation of start and stop of PCI
and CPU modules). When the process is complete, the following event log will be
output:
Source:
Type:
Event ID:
Description: Memory consistency check has completed memory scan.
LED
LED
LED
srabid
Information
4137
CPU module#1
(Stopped)*
Red
-
CPU module#1
(Started)
Red
Green
CPU module#1
(Operating)
-
Green
CPU module#2
(Operating)
-
Amber
CPU module#2
(Operating)
-
Amber
CPU module#2
(Operating)
-
Green