7-14
Troubleshooting
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
TIPS:
For error messages on optional PCI board, refer to the manual provided with those options.
On-screen error message
0200 Failure Fixed Disk
0210 Stuck Key
0211 Keyboard error
0212 Keyboard Controller
Failed
0213 Keyboard locked -
Unlock key switch
0220 Monitor type does not
match CMOS - Run
SETUP
0230 System RAM Failed at
offset
0231 Shadow RAM Failed at
offset
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive error
Cause
•
Configuration error in Setup
menu.
•
Hard disk is faulty.
•
CPU module board is faulty.
•
PCI module board is faulty.
Keyboard connection error
Keyboard is faulty.
Keyboard controller is faulty.
Keyboard is locked.
Illegal monitor type is
specified.
DIMM is faulty.
DIMM is faulty.
Action
•
Check configuration in Setup
menu.
•
Replace the hard disk.
•
Replace the CPU module
board.
•
Replace the PCI module
board.
•
Disconnect the keyboard
and connect it back again.
•
Replace the keyboard.
•
Replace the PCI module
board.
•
Check the keyboard
connection.
•
Restart the server.
•
Replace the PCI module
board.
Unlock the key switch.
•
Select "Get Default Value"
from the Setup menu.
•
Clear the CMOS data.
•
Replace DIMM.
•
Replace the CPU module
board.
•
Replace DIMM.
•
Replace the CPU module
board.