Post Error Messages - NEC Express 5800/320Lc User Manual

Nec server user's guide
Table of Contents

Advertisement

7-14
Troubleshooting

POST Error Messages

Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
TIPS:
For error messages on optional PCI board, refer to the manual provided with those options.
On-screen error message
0200 Failure Fixed Disk
0210 Stuck Key
0211 Keyboard error
0212 Keyboard Controller
Failed
0213 Keyboard locked -
Unlock key switch
0220 Monitor type does not
match CMOS - Run
SETUP
0230 System RAM Failed at
offset
0231 Shadow RAM Failed at
offset
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive error
Cause
Configuration error in Setup
menu.
Hard disk is faulty.
CPU module board is faulty.
PCI module board is faulty.
Keyboard connection error
Keyboard is faulty.
Keyboard controller is faulty.
Keyboard is locked.
Illegal monitor type is
specified.
DIMM is faulty.
DIMM is faulty.
Action
Check configuration in Setup
menu.
Replace the hard disk.
Replace the CPU module
board.
Replace the PCI module
board.
Disconnect the keyboard
and connect it back again.
Replace the keyboard.
Replace the PCI module
board.
Check the keyboard
connection.
Restart the server.
Replace the PCI module
board.
Unlock the key switch.
Select "Get Default Value"
from the Setup menu.
Clear the CMOS data.
Replace DIMM.
Replace the CPU module
board.
Replace DIMM.
Replace the CPU module
board.

Advertisement

Table of Contents
loading

Table of Contents