An unavailable disk is displayed on Disk Management:
→ Follow the instructions on the table below:
Disk status
Primary PCI module's status LED2 and DISK ACCESS LED illuminate amber after
startup:
Is the mirroring of the hard disks broken?
→ See [Disk Management] and if the mirror is broken, reconfigure it.
For mirroring configuration, see "DISK OPERATIONS" in Chapter 3 "Windows
Setup Operation."
Other than disk failure, the mirror may be removed at startup after the following
operations:
The duplication process of Baseboard Management Controller (BMC) is executed
srabid
16395
x is now STATE_BROKEN / REASON_BELLOW_MTBF ("x"
is a device number.)
Description
[Foreign]
appears
loading a dynamic disk
which has been used in a
different system.
[Missing] appears when a
dynamic disk is damaged or
removed.
[Not
Initialized]
when the disk is not signed.
Started the server after shutdown with the PCI module in simplex mode
Started NEC Express5800/ft series when the BMC status LED was blinking
when
[To use the disk's data]
Referring to Chapter 3 "Windows
Setup and Operation", import the disk.
[To change the disk to an available
disk]
To use this disk, it needs to be
initialized. It will become available
after initialization.
<Note>
Initialization erases all data on the disk.
If there is important data, back up data
before initialization.
If there is a volume on the missing
disk, break the mirror on that disk.
Then right-click the [Missing] disk and
perform [Remove disk].
appears
Right-click the disk and perform
[Initialize Disk]. The disk will become
available.