364xS User's Manual

Sensor Zero trim by HHT

Sensor Zero trim by Hand Held Terminal is available. Please refer to the device manual for the right
operations.

Sensor Zero trim by PC

Sensor Zero trim by PC is available using dedicated Software. ABB can provide the references and the
Software. Please refer to the Software instructions for the right operations.

Sensor Low Trim

The Sensor Low trim provide the correct offset of the factory characterization. The transmitter shall be within
five percent of the true value.
If the PV scaling has been performed the sensor trim is not available.
Reset the PV scaling before continuing the Sensor trim.

Sensor Low trim by Digital LCD Integral Display

Set the transmitter applied pressure as for Low trim value and wait for a stable value. Navigate the Digital
LCD Integral Display menu, select
values is available. To modify select
confirm with
Next.
Repeat the operation for the seven digits and confirm with
The first digit is the sign (- or space for +) and one digit can be the dot. The Maximum and Minimum values
are indicated on the Display as reference.
Digital LCD Integral Display Keys sequence to Low Trim the sensor: 6 – 1 – 1 – Edit

Sensor Low trim by HHT

Sensor Low trim by Hand Held Terminal is available. Please refer to the device manual for the right
operations.

Sensor Low trim by PC

Sensor Low trim by PC is available using dedicated Software. ABB can provide the references and the
Software. Please refer to the Software instructions for the right operations.

Sensor High trim

Adjustment of the Sensor high trim value provides a slope correction to the characterization curve based on
the low trim value.
If the PV scaling has been performed the sensor trim is not available.

Sensor High trim by Digital LCD Integral Display

Set the transmitter applied pressure as for High trim value and wait for a stable value. Navigate the Digital
LCD Integral Display menu, select
values is available. To modify select
confirm with
Next.
Repeat the operation for the seven digits and confirm with
The first digit is the sign (- or space for +) and one digit can be the dot.
Note: the Maximum and Minimum values are indicated on the Display as reference.
Digital LCD Integral Display Keys sequence to High Trim the sensor: 6 – 1 – 2 – Edit

Sensor High trim by HHT

Sensor High trim by Hand Held Terminal is available. Please refer to the device manual for the right
operations.
Calibrate
>
Sensor Trim
Edit
then scroll the desired value with the up and down keys and
Reset the PV scaling before continue the Sensor trim.
Calibrate
>
Sensor Trim
Edit
then scroll the desired value with the up and down keys and
>
Lower Sensor Trim
and the Sensor Low trim
OK.
>
Upper Sensor Trim
and the Sensor High trim
OK.