364xS User's Manual
The Main Menu, the Sub Menu, the Sub Sub Menu and the Utility view are also indicated on the display with
a number. The menu navigation can be described also as a sequence of the corresponding numbers that is
In any case the following table better details the available functions. The instructions of this manual further
define the Digital LCD Integral Display menu sequence to run an operation.
Display indication
Easy Setup
Language
Pressure Polarity
Engineering Unit
Set LRV
Set URV
Transfer Function Type
Lin Point
Low Flow Cut Off
Auto-Set Zero Scaling
Damping
Device Config
Rerange
Rerange with pressure
Set LRV (0%)
Set URV (100%)
Rerange no pressure
Engineering Unit
Set LRV
Set URV
Percentage Rerange
Set LRV (0%)
Set URV (100%)
PV Scaling
Auto-Set Zero Scaling
Note
called "Digital LCD Integral Display Keys sequence"
Description
This function helps the end user to run the
instrument basic configuration
Set the display language
Set the pressure transmitter High pressure side
Set the Engineering Variable unit
Set the Lower Range Value
Set the Upper Range value
Set the transmitter output transfer function
Set the point up to the output is linear with input if
the Square root is set
Set the point up to the output is zero for any input
value, when square root is selected
Set the Primary Variable at Zero
Set the damping value
This function provides all the settings related to the
device configuration
This function provides the transmitter rerange
This function provides the transmitter rerange
when a pressure source is available
Set the Low Range Value at the applied pressure
Set the Upper Range Value at the applied pressure
This function provides the transmitter rerange
when no pressure source is available
Select the engineering units for the Engineering
variable
Set the Lower Range Value at the defined value
Set the Upper Range Value at the defined value
This function provides the transmitter rerange
when any pressure source is available related to
the percentage value
Set the Lower Range Value at the defined value in
percentage
Set the Upper Range Value at the defined value in
percentage
This function provides the Primary Variable Scaling
Shift the primary variable to zero
41
Level
Type
Main Menu
Utility
Enumerated
Utility
Enumerated
Utility
Enumerated
Utility
Numerical
Utility
Numerical
Utility
Enumerated
Utility
Numerical
Utility
Numerical
Utility
Auto Adjust
Utility
Manual Adjust
Main Menu
Sub Menu
Sub Sub
Menu
Utility
Auto Adjust
Utility
Auto Adjust
Sub Sub
Menu
Utility
Enumerated
Utility
Numerical
Utility
Numerical
Sub Sub
Menu
Utility
Numerical
Utility
Numerical
Sub Menu
Utility
Auto Adjust
Operation