ABB MKey RFID Series Product Manual

Rfid dual interlock safety switch with guard locking

Advertisement

Quick Links

SAFETY PRODUCTS
RFID dual interlock safety switch with
guard locking
MKey RFID-series
Product Manual
2TLC010088M0201
Rev.A
PRODUCT MANUAL
new.abb.com/low-voltage/products/safety-products

Advertisement

Table of Contents
loading

Summary of Contents for ABB MKey RFID Series

  • Page 1 — SAFETY PRODUCTS RFID dual interlock safety switch with guard locking MKey RFID-series Product Manual 2TLC010088M0201 Rev.A PRODUCT MANUAL new.abb.com/low-voltage/products/safety-products...
  • Page 2 ABB with any questions or comments. Suitability for use ABB shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. Third party certificates for the products are available at https://new.abb.com/low-voltage/products/safety-products.
  • Page 3: Table Of Contents

    Table of Contents Introduction ........................4 Scope ................................ 4 Audience ..............................4 Prerequisites ............................4 Special notes ............................4 Overview ..........................5 General description ..........................5 Safety regulations ........................... 5 Function description ..........................6 Connections ........................7 Installation and maintenance ................... 8 Installation ...............................
  • Page 4: Introduction

    This document is intended for authorized personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: • Basic knowledge of ABB safety products. • Knowledge of safety devices and safety locks. • Knowledge of machine safety.
  • Page 5: Overview

    Overview General description MKey RFID interlock switches are designed to provide position interlock detection for moving guards. It is designed to fit the leading edge of sliding, hinged, or lift off machine guards. The actuator is fitted to the moving part of the guard and is aligned to the switch entry aperture. The possibility to lock the switch in the protective position prevents unwanted access to machinery until hazardous operations have ceased.
  • Page 6: Function Description

    It is easy to obtain the highest level of safety for the electrical part with the dual interlock actuator and the two OSSD outputs, but an ABB bolt- or rotary-handle accessory for MKey RFID is recommended to meet the mechanical requirements of relevant safety standards.
  • Page 7: Connections

    Connections See “Installation and Maintenance” for more information regarding installation. Connections MKey…RF & MKey…RFQC – Dual interlock safety switch with guard lock internal schematic. 2TLC010088M0201 Rev. A...
  • Page 8: Installation And Maintenance

    Installation and maintenance Installation The installation of all ABB Electrification safety dual interlock switches must be done in accordance with a risk assessment for the individual application. Installation must only be carried out by competent personnel and in accordance with these instructions.
  • Page 9: Rfid Code Teach-In Procedure

    62061, to confirm that all the safety functions are working properly. Warning! In case of breakdown or damage to the product, contact the nearest ABB Electrification Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
  • Page 10: Minimum Safety Distance

    Minimum safety distance When using interlocking guards without guard locking to safeguard a hazard zone, the minimum allowed safety distance between the guarded opening and the hazardous machine must be calculated. To ensure that the hazardous machine motion will be stopped before it can be reached, the minimum safety distance is calculated according to EN ISO 13855 (“Positioning of safeguards with respect to the approach speeds of parts of the human body”).
  • Page 11: Functions

    Where the Risk Assessment for the application permits, non-latching escape release versions of the MKey RFID series enable quick release of the switch lock in case of emergency. The switch can be mounted such that access to the release button is available from inside the active guard area.
  • Page 12: Disassembly And Disposal

    Disassembly and disposal Disassembly The MKey RFID dual interlock device with guard locking must be disassembled in its de-energised state, no power. Disposal The MKey RFID dual interlock device with guard locking must be disposed of in accordance with the national legislation and regulation. 2TLC010088M0201 Rev.A...
  • Page 13: Model Overview

    Model overview Type Product ID Description MKey9RF 2TLA050007R0602 MKey9RF - No actuator - Plastic with M20 entry MKey9RFQC 2TLA050007R2602 MKey9RFQC - No actuator - Plastic with M12-quick- connect MKey8RF 2TLA050011R0612 MKey8RF - No actuator - Die cast with M20 entry MKey8RFQC 2TLA050011R2612 MKey8RFQC - No actuator - Die cast with M12-quick-...
  • Page 14: Accessories

    2TLA050040R0613 Stainless steel rear escape handle RIGHT Pilot devices For the MKey10RF… 22 mm push buttons, emergency stop buttons and blanking plugs are ordered separately. More information can be found at ABB Safety Products - Pilot devices http://new.abb.com/low-voltage/products/pilot-devices 2TLC010088M0201 Rev.A...
  • Page 15: Dimensions

    Dimensions MKey9RF MKey8RF 2TLC010088M0201 Rev. A...
  • Page 16 MKey8ZRF MKey10RF / MKey10RFER 2TLC010088M0201 Rev.A...
  • Page 17 Actuators Flexible Standard MKey8(Z)RF & MKey9RF Die-cast & Stainless steel handle (same for Left and Right versions) 2TLC010088M0201 Rev. A...
  • Page 18 MKey10RF(ER) Die-cast handle (same for Left and Right versions) 2TLC010088M0201 Rev.A...
  • Page 19 Rear escape handle Die-cast & Stainless steel (same for Left and Right versions) Slide bolt MKey8RF & MKey9RF (same for Left and Right versions) 2TLC010088M0201 Rev. A...
  • Page 20 Slilde bolt MKey10RF(ER) (same for Left and Right versions) 2TLC010088M0201 Rev.A...
  • Page 21 Spring loaded catch for Slide bolts Handle for inside operation for slide bolt Note: All measurements in millimetres. 2TLC010088M0201 Rev. A...
  • Page 22: Technical Data

    Technical data Manufacturer Address ABB Electrification Sweden AB SE-721 61 Västerås Sweden Information Standards IEC 60947-5-1, IEC 60947-5-3, ISO 14119, ISO 13849- 1, IEC 62061, UL 60947-5-1 Electrical characteristics Supply Voltage 24 V DC (+/- 10%) SELV/PELV or Class 2 Power Consumption R+ (50 mA Max.)
  • Page 23 Maximum screw torque: 0.7 Nm Screwdriver bits: Slot size 3.5x0.8 mm Operating Temperature Operation: -25°C to +40°C (continuous solenoid voltage) Storage: -25°C to +80°C Humidity range Tested 55C, 93% R.H. 35 to 85% (with no icing and condensation) Altitude 2000 m (max) Mechanical Life Expectancy 2.5 x 10 cycles...
  • Page 24 Safety Classification for Guard position and lock monitoring : These values are correct provided the OSSD outputs are connected to a suitable logic device, for example, ABB Electrification Sentry safety relays. Both channels must be used. Characteristic data according to IEC 62061:2021 (used as a subsystem)
  • Page 25: Declaration Of Conformity

    Declaration of conformity 2TLC010088M0201 Rev. A...
  • Page 26 2TLC010088M0201 Rev.A...

Table of Contents