364xS User's Manual
Display indication
Set Display LRV (0%)
Set Display URV (100%)
Display Transfer Func
Security
Display Protection
Change Password
Totalizer
Totalizer status
Reset
Permanent Totalizer
Reset
Tot. Protection
Change Password
Batch Totalizer
Totalizer Settings
Totalizer LRV (0%)
Totalizer URV (100%)
Input Eng. Units
Permanent Eng. Unit
Engineering Unit
Custom Unit
Conversion Factor
Batch Eng. Unit
Engineering Unit
Custom Unit
Conversion Factor
Bidirectional Flow
Communication
HART Tag
Descriptor
Message
Polling Address
Description
Set the display to show 0% at the defined Lower
Range Limit
Set the display to show 100% at the defined Upper
Range Limit
Set the display transfer function (indipendent from
the output transfer function)
This function set the security features
Set the protection or remove the protection
Modify the password
This function provides all the totalizer settings
Set the totalizer status
Reset the totalizer value
This function provides the setting of the
permanent totalizer
Reset the permanent totalizer
Set the permanent totalizer protection
Modify the permanent totalizer password
Set the batch totalizer parameter
This function provides the totalizer setting
Set the Totalizer Lower Range Value
Set the Totalizer Upper Range Value
Set the Totalizer engineering unit
This function provides the Permanent Totalizer
engineering unit
Set the Permanent Totalizer engineering unit
among a predifined list
Set the Permanent Totalizer engineering unit in the
custom version
Set the Permanent Totalizer Conversion Factor
This function provides the Batch Totalizer
engineering unit
Set the Batch Totalizer engineering unit using a
predefined list
Set the Batch Totalizer engineering unit in the
custom version
Set the Batch Totalizer Conversion Factor
Defines the sum or the subtraction of the positive
and negative flow (the bidirectional transfer
function has to be selected)
This function provides all the Communication
settings
Set the Tag value in the transmitter database
Set the Descriptor value in the transmitter
database
Set the Message value in the transmitter database
Set the Polling Address value in the transmitter
database
43
Level
Type
Utility
Numerical
Utility
Numerical
Utility
Enumerated
Sub Sub
Menu
Utility
ASCII String
Utility
ASCII String
Main Menu
Utility
Enumerated
Sub Menu
Sub Sub
Menu
Utility
Auto Adjust
Utility
ASCII String
Utility
ASCII String
Utility
Auto Adjust
Sub Menu
Utility
Numerical
Utility
Numerical
Utility
Enumerated
Sub Sub
Menu
Utility
Enumerated
Utility
ASCII String
Utility
Numerical
Sub Sub
Menu
Utility
Enumerated
Utility
ASCII String
Utility
Numerical
Utility
Enumerated
Main Menu
Utility
ASCII String
Utility
ASCII String
Utility
ASCII String
Utility
Enumerated
Operation