The arc voltage is affected by the impedance in the welding cables. The impedance
is affected by the length and area of the cables as well as by how they are routed.
This is especially prominent during AC welding.
Compensation for the voltage drop with long cables is maintained if the actual cable
length is specified.
The total cable length (weld cable and connector together) must be fed in.
Note! When using two cables, the areas must be combined for both cables.
This function is active during the start process before the power source has received
a measurement value that it can regulate at.
If "Max OCV" has been selected this function is inactive.
8.5

Maintenance

Main menu ³ Configuration menu ³ Maintenance
In this menu you set how often the contact tip is to be changed. Specify the number
of weld starts after which the tip is to be changed by selecting the CONTACT TIP
CHANGE INTERVAL row and pressing ENTER. Change the value using the setting
knobs. When the interval has been passed, fault code 54 is displayed in the error
log. Reset by pressing RESET.