Delete Error Message; Units; Description Of Fault Management Codes - ESAB PEK A2 Instruction Manual

Hide thumbs Also See for PEK A2:
Table of Contents

Advertisement

GB
9.1.1

Delete error message

In order to delete error messages, press DELETE ALL. All rows are emptied from the
error log.
9.1.2

Units

2
= Power source
6
= Wire feed and travel motion (motor board)
8
= control panel
9.1.3

Description of fault management codes

The fault management codes that users can correct themselves are given below. If
another code appears, restart the machine and if the error persists, contact a service
technician.
Error
Description
code
6
High temperature
The power source has overheated and cancels welding. Welding is permitted again when
the temperature falls below the maximum temperature parameter.
Action: Check that the cooling air inlets or outlets are not blocked or clogged with dirt.
Check the duty cycle being used, to make sure that the equipment is not being overloaded.
If the error persists, send for a service technician.
7
Low welding current
The weld arc has been shut down due to too low welding current during the welding
process.
Action:Turn off the mains power supply to reset the unit. If the error persists, send for a
service technician.
8
Low battery voltage
Battery voltage too low. If the battery is not replaced, all stored data will be lost.
This error does not disable any functions.
Action: Send for a service technician to replace the battery.
11
Speed error on a motor, (wire feed, travel motor)
A motor cannot maintain its speed. Welding stops.
Action: Check that the wire feed has not jammed or runs too fast. If the error persists,
send for a service technician.
bi24d1ea
ERROR LOG
Index
Date
1
081120
2
081120
3
081121
Error in battery−driven memory
DELETE
ALL
− 43 −
Time
Unit
11:24:13
8
10:24:18
8
13:24:18
8
Error
19
18
17
QUIT