Quality Data Log To File; Soft Key Configuration - ESAB PEK A2 Instruction Manual

Hide thumbs Also See for PEK A2:
Table of Contents

Advertisement

GB
Then scroll to the next row, ASSOCIATED WELD DATA. Here you can browse
through the weld data sets that are stored in the weld data memory. Selected the
desired weld data number using the setting knobs. Press STORE to save. To delete
the stored set, press DELETE.
8.2.2

Quality data log to file

In the QUALITY DATA
LOG TO FILE menu it
is possible to activate it
with ON.
Read more about settings for the quality function in chapter 9.7.
8.2.3

Soft key configuration

We have previously described the control panel's "soft" keys. For Submerged Arc
Welding (SAW) and for Gas Metal Arc Welding (GMAW) welding, the user has the
possibility of setting the function of these keys by selecting from a list of set options.
There are eight soft keys that can be allocated a function.
It is possible to choose between the following options:
None
S
S
Gas purge / Flux valve
S
See set values in the measurement menu
S
Relay 1
Sets relay output no.1 on the motor circuit board, which can be used for any
function by the customer.
In the display screen
there are two columns;
one for SOFT KEYS
and one for FUNC-
TION.
bi24d1ea
GENERAL CONFIGURATION
FAST MODE SOFT BUTTONS
QUALITY DATA LOG TO FILE
SOFT KEYS SETUP"
AUTO SAVE MODE
UNIT OF LENGTH
SOFT KEYS SETUP
SOFT KEYS
S1
S2
S3
S4
S1 2ND FUNCT
S2 2ND FUNCT
S3 2ND FUNCT
S4 2ND FUNCT
− 35 −
1
ON
OFF
METRIC
QUIT
FUNCTION
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
QUIT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pek a6

Table of Contents