9.3.12 Diagnostics of electromagnetic clutch problems

10 A fuse blown
Low supply voltage (less than 12 VDC
to the clutch)
Incorrect resistance values
Inadequate power supply
Excessive backlash between rotor and
armature
PARK
Problem
1) Symptom: The clutch does not engage.
Chapter
9 - ELECTRICAL SYSTEM
Probable cause
• Low coil resistance
• Faulty battery
• Faulty charging system
• Faulty wiring or connections of the
PTO switch
• Faulty battery
• Faulty charging system
• Faulty wiring or connections of the
PTO switch
• Damaged winding
• Clutch cables broken
• Faulty electrical system
• End of the clutch life
3
5
Solution
• Replace the clutch
• Replace the battery
• Repair or replace.
• Check, repair or replace
• Replace the battery
• Repair or replace.
• Check, repair or replace
• Replace the clutch
• Repair or replace.
• Measure the clutch coil resist-
ance and the voltage supply. If
both are correct, the electrical
system is defective. Repair or
replace.
• Replace the clutch