Stiga 2021 Edition PARK 320 P Workshop Manual page 107

Table of Contents

Advertisement

WORKSHOP MANUAL
PARK
Problem
7) Irregular operation of the
electrical circuit.
8) The motor shuts off during
use.
9) Intervention of the 20 A
fuse.
10) The clutch does not
engage.
9 - ELECTRICAL SYSTEM
Probable cause
Insufficient charging.
Overvoltage charging.
Battery charger fuse blown.
Intervention or failure of safety
devices.
Random detachment of some
electrical cables.
Engine running consent is miss-
ing.
Uncertain or missing mass on the
charge controller.
Overvoltages from malfunction of
the regulator.
Battery disconnected or dam-
aged during use.
Short circuit or overload on the
power side of the system (igni-
tion block, starter relay, lights and
charging connector).
Short circuit on the front socket.
20A fuse blown.
Power circuit failure
Chapter
Solution
Check that the charging cable is
not disconnected and recharge the
battery.
Check that there are no leaks
caused by cables with deteriorated
insulation and recharge the battery.
Check the charging circuit.
Check the charging circuit.
Replace the fuse (30 A) and check
the charging circuit.
Check the operation of the micros-
witches and their wiring.
Check all the wiring.
Having made sure that the consent
conditions are respected, check all
the microswitches and the relative
wiring.
Check the ground connections and
the fixing screws of the regulator.
Check the charging circuit.
Check the battery and wiring.
Look for the defective user and
replace it.
Check the sockets.
Replace the fuse.
Check and / or replace the PTO
relays
Check and / or replace the operator
presence switch
EDITION
PAGE
2020
107 /
124
[
...]
[9.3.10]
[9.3.2]
[2.5.6]
[9.3.10]
[9.3.1]
[9.3.2]
[9.3.6]
[9.3.10]
[9.3.8]
[9.3.5]