SSP 7.1 Setup and Control Software, cont'd

Factory Defaults

The Reset Device button undoes any user changes and resets all
values to the factory defaults.

Dynamic Range Compression

(Only with Dolby Digital and DTS source formats that have a
Dynamic Range Compression flag)
These radio buttons allow a choice of Off, Minimum,
and Maximum. The default setting is Off. For more
information, see page 4-7.

Mono Mode Settings

Two advanced configurations apply only to mono sources
or outputs:

Mono Source (applies to Analog Input #5 only)

If two mono signals are input on input 5 (analog), the user
can choose whether the left input, right input, or mixed left
and right inputs become the source for the mono decoding
mode. By default, the L + R (Sum) selection is used.

Mono Output

These buttons let the user select whether mono signals are
output to the center channel or a dual mono signal is sent
to the right and left front channels. By default, the center
channel is used.

Dolby Pro Logic II/IIx Music Settings

These controls allow the user to adjust global
settings for the Dolby Pro Logic II/IIx Music
listening mode. Dolby Pro Logic II Music is
used for any stereo music recordings. The
music mode provides an additional set of
commands to tailor the sound to individual
listening tastes. For more information about
this listening mode, see page B-8.

Dimension Control

These buttons allow the user to choose Front,
Neutral, or Rear (default Neutral). For more
information, see page 4-6.