IUH-F190-V1-*
Commissioning
Country Identifiers for IUH-F190-V1-FR2
Country
Identifier
02
03
07
08
09
10
11
12
13
14
For technical details on the regional settings, see chapter 4.3. For an example of reading and
writing the country identifier, see chapter 6.3.
6.3

Device Settings

Warning!
Device not configured or configured incorrectly
Configure the device prior to commissioning. A device that has not been configured or
configured incorrectly may lead to faults in the plant.
Before commissioning the read/write head, you need to configure the control interface. To do
so, read the "Commissioning" chapter of the manual for your control interface.
Configure the read/write heads with the described system commands (see chapter 7.6.2). For
a parameterization example, see see chapter 6.4.
Caution!
Uncontrolled triggered processes
Before commissioning the device, make sure that all processes are running smoothly;
otherwise damage may occur in the plant.
6.4

Operation via the Command Interface

This section shows you how to operate the read/write head using an IDENTControl control
interface with serial interface. The commissioning procedure described relates to the RS-232
interface and involves a PC. The examples include the syntax for coding the commands and
parameters via the Ethernet TCP/IP and PROFIBUS/PROFINET interfaces. Further details
about these codes and the factory settings for your IDENTControl control interface can be
found in the manual.
34
Occupied Frequency Bandwidth
Frequency Access Method
902 MHz ... 928 MHz
Frequency hopping spread spectrum
920 MHz ... 925 MHz
Frequency hopping spread spectrum
915 MHz ... 928 MHz
Frequency hopping spread spectrum
916.7 MHz ... 920.5 MHz
Programmable frequency list
917.2 MHz ... 920.4 MHz
Frequency hopping spread spectrum
920 MHz ... 926 MHz
Frequency hopping spread spectrum
921.5 MHz ... 928 MHz
Frequency hopping spread spectrum
920 MHz ... 925 MHz
Frequency hopping spread spectrum
919 MHz ... 923 MHz
Frequency hopping spread spectrum
920 MHz ... 925 MHz
Frequency hopping spread spectrum
Country or Region
United States
Canada
Mexico
Argentina
Colombia
China
Brazil
Japan
South Korea
Australia
New Zealand
Thailand
Hong Kong
Malaysia
Singapore
Vietnam

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iuh-f190-v1-euIuh-f190-v1-fr

Table of Contents