IUH-F190-V1-*
Operation
Number of Attempts "Tries Allowed" TA
This parameter sets the permitted number of write or read attempts, or outputs the permitted
number of attempts.
ParamTyp:
Default:
Value range:
Example:
WP1UTA.00.01.01 permits precisely one attempt (= no repeats)
WP1UTA.00.01.03 permits 3 attempts
RP1UTA.00.00 outputs the permitted number of attempts
If the permitted number of write or read attempts between the read/write head and the tag is
increased, this results in:
More reliable reading and writing.
Increased response time.
7.7

Error/Status Messages

Status Description
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
58
TA
TA = 2
1 ... 255
The command was executed correctly.
Reserved
Switch-on message, reset was executed.
Reserved
The command is incorrect or incomplete.
The parameter is not in the valid area.
No read/write tag in the measurement range.
Hardware error, e.g., error during self-test or read/write head defective.
Internal device error.
Reserved
The parameterized tag type is not compatible with the connected read head.
Singleframe protocol: there are multiple tags in the measurement range (IUH*).
Multiframe protocol: There are multiple tags in the measurement range that have the
same UII/EPC (IUH*).
Indicates the output of additional information (see "Output Additional Information,
"Information" IF" on page 51).
Reserved
Reserved
Internal buffer overflow; execute reset.
Indicates the end of an output in the multiframe protocol (see "Protocol Mode QV" on
page 54).