IUH-F190-V1-*, IUT-F190-R4-V1* Contents Introduction........................ 6 Content of this Document ................6 Target Group, Personnel ................6 Symbols Used ....................7 Certificates and approvals..................8 Declaration of Conformity (RE Directive 2014/53/EU) ....... 8 FCC-Information..................... 8 IC-Information ....................9 UL Information ....................9 Approval Thailand..................
Page 4
IUH-F190-V1-*, IUT-F190-R4-V1* Contents Countries of Use ..................17 3.3.1 European Union ................17 3.3.2 Argentina..................17 3.3.3 Australia ................... 18 3.3.4 Brazil ....................18 3.3.5 Canada .................... 18 3.3.6 China....................18 3.3.7 Hong Kong ..................19 3.3.8 India ....................19 3.3.9 Indonesia ..................
IUH-F190-V1-*, IUT-F190-R4-V1* Introduction Introduction Content of this Document This document contains information required to use the product in the relevant phases of the product life cycle. This may include information on the following: • Product identification • Delivery, transport, and storage •...
IUH-F190-V1-*, IUT-F190-R4-V1* Introduction Symbols Used This document contains symbols for the identification of warning messages and of informative messages. Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid prop- erty damage.
Note A Declaration of Conformity can be requested from the manufacturer or downloaded from www.pepperl-fuchs.com. The product manufacturer, Pepperl+Fuchs AG, 68307 Mannheim, has a certified quality assur- ance system that conforms to ISO 9001. ISO9001 FCC-Information FCC ID: IREIUHF190V1B This device complies with Part 15 of the FCC Rules.
. Supply must be PELV (Protective Extra Low Voltage). The overvoltage category II is applied. This is the case if Pepperl+Fuchs IDENTControl control interface is used. Protection class IP67 is not included in the UL approval. The protection class is tested by Pep- perl+Fuchs AG.
IUH-F190-V1-*, IUT-F190-R4-V1* Certificates and approvals Approval Thailand Device type: IUH-F190-V1-FR2-12 Part number: 309845 (This telecommunication equipment conforms to the standard or technical requirements of NBTC.) (This radiocommunication equipment has the electromagnetic field strength in compliance with the Safety Standard for the Use of Radiocommunication Equipment on Human Health announced by the National Telecommunications Commission.)
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description Product Description RFID Frequency Bands The following diagram shows the position of the different frequency bands used for RFID. The read/write heads described in this manual operate in the frequency range from 865 MHz ... 868 MHz and from 902 MHz ... 928 MHz, highlighted in color. 1000 10000 Frequency...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.2.3 Memory Structure of a Tag in Accordance with EPC Gen 2 (ISO/IEC 18000-63) [7:0] DSFID [7:0] Commands Read / write head Memory module [15:0] SR/ER Bank 11 USER [31:16] SW/EW Bank 10 SF/EF SS/ES Bank 01 UII/EPC Optional XPC_W2 [15:0]...
Page 13
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description Bank 00: Password Management The segment Bank 00 contains the password management information, comprising the access password and the kill password. The read/write head manages the kill password with the standard read/write commands SW and SR. The access password is not supported. See "Single Read Words SR"...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.2.4 Elektronic Product Code (EPC) The electronic product code is a unique identifier in the form of a sequence of numbers. The number sequence has a set structure and a length of 64 bits, 80 bits, 96 bits, or longer (depending on the EPC Ident number used).
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.2.7 Frequency Hopping Spread Spectrum With FHSS (Frequency Hopping Spread Spectrum), the information to be transmitted is distrib- uted successively through multiple channels. Only one frequency channel is used at any one time. This results in a larger bandwidth for the entire signal, in spite of the fact that each chan- nel has a smaller bandwidth.
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description Countries of Use Note Transmission License A country-specific transmission license is required to operate the read/write head. In the European Union, the manufacturer's declaration of conformity constitutes an adequate license. All currently valid transmission licenses can be found in the datasheet for the respective read/write head at www.pepperl-fuchs.com.
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.3.3 Australia In Australia, the use of RFID in the UHF range is regulated as follows: • UHF frequency range: 920 MHz ... 926 MHz • Radiated Power: 3 … 1000 mW ; Default = 125 mW EIRP EIRP •...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.3.7 Hong Kong The regulations for the UHF frequency range of 865 MHz to 868 MHz in Hong Kong are the same as the regulations for the UHF frequency range in the European Union. See chapter 3.3.1.
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.3.10 Japan In Japan, the use of RFID in the UHF range is regulated as follows: • UHF frequency range: 916.7 MHz … 920.5 MHz • Radiated Power: 3 … 125 mW ; Default = 125 mW EIRP EIRP •...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.3.14 Mexico The regulations for the UHF frequency range in Mexico meet the requirements for the UHF fre- quency range in the U.S.. See chapter 3.3.20. 3.3.15 New Zealand In New Zealand, the use of RFID in the UHF range is regulated as follows: •...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.3.17 Singapore In Singapore, the use of RFID in the UHF range of 866 MHz to 868 MHz is regulated in accor- dance with EN 302208. • UHF frequency range: 866 MHz … 868 MHz • Radiated Power: 3 …...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.3.19 Thailand In Thailand, the use of RFID in the UHF range is regulated as follows: • UHF frequency range: 920 MHz ... 925 MHz • Radiated Power: 3 … 1250 mW ; Default = 125 mW EIRP EIRP •...
UHF range operating frequency. Read/write head IUH-F190-V1-* can only be used together with an IDENTControl control inter- face from Pepperl+Fuchs. Read/write heads IUT-F190-R4-V1-* do not require a control interface and can be connected by means of a point-to-point connection to a RS-485 serial interface.
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description Technical Data General Data Operating frequency Country-specific, see chapter 3.3 Light power Country-specific, see chapter 3.3 Electrical Data Current consumption 450 mA Power consumption 9 W Power supply from IDENTControl Rated operating voltage 20 ... 30 V , ripple 10 % SS, limited power source (EN60950) for IUT-F190* Surge protection...
Page 26
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description IUH-F190-V1-* The IUH-F190-V1-* read/write head is connected to the IDENTControl control interface via the M12 x 1 connector. do not connect Shield Figure 3.5 + < 30 V , < 450 mA (20 ... 30 V Data input/output A, RS-485, -7 V ...
Tighten the retaining bolt to a tightening torque of 1.6 Nm ± 0.4 Nm. Scope of Delivery • Read/write head • Quick start guide Accessories 3.9.1 IDENTControl The IUH-F190-V1-* read/write head can be connected to Pepperl+Fuchs IDENTControl control interfaces. Interface Designation 4 read/write heads: Ethernet IC-KP-B17-AIDA1 2 read/write heads: PROFIBUS...
IUH-F190-V1-*, IUT-F190-R4-V1* Product Description 3.9.4 Cable connectors for the power supply Compatible M12 sockets with an open cable end for connecting the IDENTControl to a power supply are available in different lengths. Figure 3.8 Accessories Designation Length 2 m (straight socket) V1-G-2M-PUR Length 5 m (straight socket) V1-G-5M-PUR...
Device type and version in accordance with the type label • Any accessories ordered Retain the original packaging in case you have to store or ship the device again at a later date. Should you have any questions, please contact Pepperl+Fuchs. Mounting Warning! Malfunctions with pacemakers This device does not exceed the permissible limits for electromagnetic fields.
Page 31
Assurez-vous que la tête de lecture / écriture est fermement connectée à la terre. Note The installation recommendations made in this document are based on favorable conditions. Pepperl+Fuchs provides no guarantee of correct function in cross environments. Mounting the read/write head Figure 4.1...
IUH-F190-V1-*, IUT-F190-R4-V1* Installation 4.3.1 Room Orientation The alignment of the read/write tag antennae in relation to the antennae of the read/write head influences the detection range of the system. Make sure the antennae are aligned parallel to each other. Optimum alignment of the tag •...
IUH-F190-V1-*, IUT-F190-R4-V1* Installation During simultaneous operation of several read/write heads, only one read/write head may ever communicate with a tag at any given time. When arranging the read/write heads, make sure that the measurement ranges do not overlap. You can enlarge or reduce the size of the mea- surement range by changing the transmitting power.
IUH-F190-V1-*, IUT-F190-R4-V1* Installation Warning! Incorrect electrical connection Damage to the device or plant caused by incorrect electrical connection. Check all connections in the plant before commissioning the device. After connecting the supply voltage, the POWER LED on the device lights up green. If the LED does not light up on the device, the power supply is not connected correctly.
IUH-F190-V1-*, IUT-F190-R4-V1* Commissioning Commissioning Definitions 5.1.1 Display Angle brackets contain the abbreviated meaning of a command structure, e.g., <Data> The index or .xx denotes a hexadecimal number. denotes a value in the hexadecimal system, specified in ASCII characters. ASCII Example: 10 corresponds to A corresponds to 41 .
IUH-F190-V1-*, IUT-F190-R4-V1* Commissioning <WordAddr>: Word start address in the read/write tag, 4 hex characters, ASCII range from "0000h" to "FFFF", depending on tag type <WordNum>: Number of words to be read or written, 2 hex characters. ASCII Range from "01" through "20" depending on the tag type, word lengths are 4 bytes Sensor Settings Warning!
Page 37
IUH-F190-V1-*, IUT-F190-R4-V1* Commissioning Enhanced Read Read-Only Code Send the enhanced read read-only code command to the read/write head. The "RF ON" LED on the read/write head lights up blue. Serial Ethernet PROFIBUS/PROFINET Command: .00.04.1D.03 .1D.03 Confirmation: .00.06.1D.03.FF.0B .1D.03.FF.0B Response: .35.31 .00.06.1D.03.05.0C .1D.03.05.0C Table 5.1...
Page 38
IUH-F190-V1-*, IUT-F190-R4-V1* Commissioning Parameterizing the Read/Write Head Requesting and Setting the Transmission Power Read out the read/write head's transmission power with the read parameter PT command: Serial Ethernet PROFIBUS/PROFINET Command: RP1UPT.00.00 .00.0A.BE.03.00.55.50.54. .BE.03.00.55.50.54.00.00 00.00 Confirmation: .00.06.BE.03.FF.33 .BE.03.FF.33 Response: .30.31.00.32 .00.0A.BE.03.00.34.00.02. .BE.03.00.34.00.02.00.32 00.32 The read/write head's set transmission power is 50 mW (32...
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Operation General The sections below contain information about the commands that relate to your read/write head. The commands are described using the example of an IDENTControl control interface with serial interface. All other generally applicable commands and error messages or status messages can be found in the manual for your IDENTControl control interface.
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Several Tags in the Measurement Range Each read or write command can access one, several, or all tags in a measurement range. The process is controlled by filter masks, which are managed via the commands Set Filter Mask (FI) and Activate/Deactivate Filter (MF).
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Abbrevia- tion Command description See "Enhanced Write Words EW" on page 44 EW, #EW See "Kill UHF Tag KI" on page 45 Filter Commands Abbrevia- tion Command description See "Set Filter Mask FI" on page 45 See "Activate/Deactivate Filter MF" on page 47 Configuration Commands Abbrevia- tion...
Page 42
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Single Read Special Read-Only Code SS This command reads the UII segment from tags according to EPC Gen2 (ISO/IEC 18000-63). Command: SS <ChanNo> 0 <CHCK> <ETX> Response: <Status> <ChanNo> <Length> <SpecialFixcode> <CHCK> <ETX> F <ChanNo> 0001 <CHCK> <ETX> Example: SS10 reads the entire UII segment.
Page 43
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Command: SP <ChanNo> <Length> <SpecialFixcode> <CHCK> <ETX> Response: <Status> <ChanNo> <NUL> <Length> <SpecialFixcode> <CHCK> <ETX> F <ChanNo> 0001 <CHCK> <ETX> The data length <Length> must be a whole number multiple of 2 octets because in accordance with EPC Gen 2 (ISO/IEC 18000-63), <UII/EPC> must be written in 16-bit words. Only the lengths 2 , ...
Page 44
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Note The memory bank (MB) parameter defines the bank accessed by this command. see "Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52. Enhanced Read Words ER Continuous attempts are made to read <WordNum> 32-bit words from the address <WordAddr>.
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Note The memory bank (MB) parameter defines the bank accessed by this command. see "Memory Module for Tag Accesses to the "Memory Bank" MB" on page 52. Note 16-Bit Read/Write Commands The read/write commands SR, ER, SW, and EW are interpreted as 16-bit versions by means of a preceding # symbol.
Page 46
IUH-F190-V1-*, IUT-F190-R4-V1* Operation <StartAddress> = Address of the bit at which the filter mask begins. Specified in hex . Val- ASCII ues: 0000 … FFFF <MaskLength> = Length of the mask in bits. The information is entered as 2 hex charac- ASCII ters.
Page 47
IUH-F190-V1-*, IUT-F190-R4-V1* Operation FI102000000018.E2.00.10 sets filter 0 so that all tags with a TID beginning with .E2.00.10 are detected. FI111100002008.22 sets filter 1 so that all tags whose UII/EPC do not begin .22 are detected. FI1010100010700.00123456789012 sets filter 0 so that the tag with the SpecialFixcode (PC+UII/EPC) 0.00123456789012 is detected.
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Filter mask Selected flag Command MF - Mode 2 In total, there are 15 tags in the measurement range of the read/write head, with three groups of five marked as either A, B, or C. The filter is set to "B" by command FI. If you execute command MF12 (Activate Filter - Mode 2), this command affects all subsequent commands.
IUH-F190-V1-*, IUT-F190-R4-V1* Operation 6.6.1 Read and Write Parameters With the read parameter (RP) and write parameter (WP) configuration commands, you can read/write the following parameters: Abbre- viation Page Parameter is readable/writeable See "Antenna Polarization AP" on page Readable/writeable See "CD Transmission Channels" on Readable/writeable for RC = 1, 4, 5, 6, page 50 Readable for RC = 2, 3, 7, 9, 10, 11, 12,...
IUH-F190-V1-*, IUT-F190-R4-V1* Operation <ParamTyp> = 2 bytes ASCII <DataLength> = Length of <Data> in command, 2 bytes binary <Data> = Optional additional information Example: RP1UE5.00.00 outputs the number of unsuccessful read attempts until status 5. Write Parameters Command WP writes configuration parameters to the read/write head. Command: WP <ChanNo>...
Page 51
IUH-F190-V1-*, IUT-F190-R4-V1* Operation This parameter reads out the number and sequence of transmission channels for the fre- quency hopping spread spectrum. ParamTyp: Default: Depending on the country-specific settings, see chapter 3.3. Value range: Depending on the country-specific settings, see chapter 3.3. Example: WP1UCD.00.04.07.0A.04.0D defines the sequence 7, 10, 4, and 13 as the permitted transmis- sion channels...
Page 52
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Output Additional Information, "Information" IF Parameter IF allows you to output additional information providing that the reading was suc- cessful and the multiframe protocol is activated. See "Protocol Mode QV" on page 55. The additional information is the RSSI value of the reading, the transmission channel used, and transmitting power of this reading.
Page 53
IUH-F190-V1-*, IUT-F190-R4-V1* Operation ParamTyp: Example: RP1UMD.00.01.01 returns the response .30.01.13.04.00.32 Explanation of the response: <Status> = 0 <ChanNo> = 1 <RSSI> =. 13 = 19 <TXChannel> =. 04 <TXPower> = .00.32 = 50 Measurement of Reflected Transmitting Power "Measure Reflection" MF This parameter measures the reflected transmitting power of the antenna and the environment.
Page 54
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Example: WP1UNC.00.01.02 allows two channels for a read attempt. RP1UNC.00.00 reads out the number of channels set. Search Algorithm Cancellation Criteria "number of tags to find" NT Parameter NT specifies the number of tags in the measurement range that the read/write head searches for.
Page 55
Parameter QV toggles the output protocol between single frame and multiframe. In single-frame protocol, the output corresponds to the Pepperl+Fuchs standard in LF and HF systems. If there is more than one tag in the measurement range, status A is output as a warn- ing.
Page 56
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Responses Depending on Protocol Mode QV Parameter QV Single-frame protocol Multiframe protocol Command Responses No tag: No tag: 5<ChanNo> F<ChanNo>0000 One tag: Two tags: 0<ChanNo><UII> 0<ChanNo><Luii><UII1> Two tags: 0<ChanNo><Luii><UII2> A<ChanNo> F<ChanNo>0002 SR, #SR No tag: No tag: 5<ChanNo>...
Page 57
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Example: WP1UQW.00.01.04 sets the Q value to 4. The read/write head therefore works with 2 = 16 time slots. RP1UQW.00.00 outputs the set Q value. Country Identifier, "Region Code" The RC parameter reads out the country identifier. ParamTyp: Value range: See the following table “country identifiers”...
Page 58
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Country Iden- Occupied Frequency Bandwidth tifier Frequency Access Method Country or Region 919 MHz – 923 MHz Malaysia Frequency hopping spread spectrum 920 MHz – 925 MHz Singapore Frequency hopping spread spectrum Vietnam 920 MHz – 923 MHz Indonesia Frequency hopping spread spectrum Table 6.2...
IUH-F190-V1-*, IUT-F190-R4-V1* Operation ParamTyp: Default: SM = 100 ms SM = 0 ms Value range: 100 ms ... 65,535 ms, 2 bytes 0 ms ... 65,535 ms, 2 bytes 1. For all FR1 read/write heads 2. For all FR2 read/write heads 3.
IUH-F190-V1-*, IUT-F190-R4-V1* Operation The IUT-F190-R4-V1-* read/write head is set to single-drop mode at the factory. Define Function DF This command is used to switch operating mode: Single-drop --> Multi-drop Command: DF42 <CHCK> <ETX> Multi-drop --> Single-drop Command: DF <DeviceNo> 41 <CHCK> <ETX> After changing the operating mode, a power supply reset or an "RS"...
IUH-F190-V1-*, IUT-F190-R4-V1* Operation The command must be executed after a configure interface CI or define function DF, so that the changes become active. Configuration Commands See chapter 6.6 and chapter 6.5 Read/Write Commands See chapter 6.4 6.7.2 Multi-drop mode In this operating mode, the read/write head immediately sends a confirmation that the com- mand has been understood.
Page 62
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Command: CI <DeviceNo> <Timeout>, <Baud> <CHCK> <ETX> Response: <Status> <DeviceNo> <CHCK> <ETX> The following settings are possible: <Timeout>: "0" ... "100" (x 100 ms, timeout in 100 ms steps) <Baud>: "1,200" , "2,400" , "4,800" , "9,600" , "19,200", "38,400" The default values are a timeout of "0"...
IUH-F190-V1-*, IUT-F190-R4-V1* Operation Error/Status Messages Status Description The command was executed correctly. Reserved Switch-on message, reset was executed. Reserved The command is incorrect or incomplete. The parameter is not in the valid area. No read/write tag in the measurement range. Hardware error, e.g., error during self-test or read/write head defec- tive.
IUH-F190-V1-*, IUT-F190-R4-V1* Service and Maintenance Service and Maintenance The device is designed and constructed to function stable over long periods of time. For this reason, regular cleaning or maintenance is unnecessary.
IUH-F190-V1-*, IUT-F190-R4-V1* Troubleshooting Troubleshooting Problem Solution Interference from several • Use the multi-plex mode of the IDENTControl control inter- read/write heads in the face direct vicinity • Change the setting of the transmission channels • Reduce the transmission power Status A message •...
IUH-F190-V1-*, IUT-F190-R4-V1* Appendix ASCII hex ASCII ASCII hex ASCII < > Detection range The read/write head has a typical detection range of around 1 meter; this range is determined by the tag used and can be adjusted by selecting the transmission power. Other influencing factors include the setup and installation of the specific application, interference from any mate- rials present (in particular metal), and the ambient conditions.
Page 68
IUH-F190-V1-*, IUT-F190-R4-V1* Appendix Antenna Diagram The antenna diagrams show the electric field strength in the far field depending on the direc- tion. The front of the read/write head points towards 0°. IUH-F190-V1-FR2* and IUT-F190-R4-V1-FR2* Horizontal Cut -180 0 dB -150 -3 dB -6 dB -9 dB...
Page 69
IUH-F190-V1-*, IUT-F190-R4-V1* Appendix Vertical Cut -180 0 dB -150 -3 dB -6 dB -9 dB -12 dB -120 -15 dB -18 dB -21 dB -24 dB -27 dB -30 dB 1. Read/write head points towards 0° Figure 9.3 - Horizontal polarization - Vertical polarization - Full width at half maximum...