IUH-F190-V1-*
Commissioning
<WordAddr>:
<WordNum>:
6.2

Initial Commissioning

All IUH-F190-V1-* read/write heads operate within their maximum frequency range from 865
MHz ... 868 MHz, or from 902 MHz ... 928 MHz, with the appropriate settings for the relevant
country. This enables the following parameters to be set according to the valid regulations for
the relevant country:
The maximum occupied bandwidth
The channel bandwidth
The channel plan used
The frequency access method
The maximum power setting
Note!
Country Identifier
The IUH-F190-V1-FR* read/write head has no valid country identifier by default. This status is
indicated by the flashing green LED. In this state, the read/write head will accept only the
command for setting the relevant country identifier. Once you have parameterized a valid
country identifier, you can begin using the read/write head.
The IUH-F190-V1-FR2-02 is supplied ex-works with the country identifier "02" for the USA,
Canada, and Mexico. Due to legal regulations, you cannot change this country identifier in the
IUH-F190-V1-FR2-02.
The IUH-F190-V1-EU is supplied ex-works with the country identifier "01" for Europe. You can
change the country identifier in the IUH-F190-V1-EU.
Note!
The country identifier set is saved in the read/write head as nonvolatile. The country identifier
setting is not affected by a reset to the factory settings. It can be overwritten with another valid
country identifier at any time.
Country Identifiers for IUH-F190-V1-FR1 and IUH-F190-V1-EU
Country
Identifier
01
04
05
06
Word start address in the read/write tag, 4 hex
from "0000h" to "FFFF", depending on tag type
Number of words to be read or written, 2 hex
from "01" through "20" depending on the tag type, word lengths are 4
bytes
Occupied Frequency Bandwidth
Frequency Access Method
865.6 MHz ... 867.6 MHz
Programmable frequency list
865.0 MHz ... 867.0 MHz
Programmable frequency list
866.0 MHz ... 868.0 MHz
Programmable frequency list
866.0 MHz ... 867.6 MHz
Programmable frequency list
characters, range
ASCII
characters. Range
ASCII
Country or Region
EU and other countries subject to EN
302208
India
Singapore, Vietnam
Russia
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iuh-f190-v1-euIuh-f190-v1-fr

Table of Contents