Troubleshooting - Pepperl+Fuchs IUH-F190-V1 Series Manual

Read / write head for identcontrol
Hide thumbs Also See for IUH-F190-V1 Series:
Table of Contents

Advertisement

IUH-F190-V1-*

Troubleshooting

9
Troubleshooting
Problem
Interference from several
read/write heads in the
local vicinity
Status A message
Device not responding,
green LED flashing
60
Solution
Change the setting of the transmission channels
Reduce the transmission power
Check whether there are multiple tags in the detection range:
Remove the tag from the detection range by placing the tag in
a sealed metal container
Repeat the read or write operation
Use filter commands
Determine whether multiple tags have the same UII/EPC
Set the correct country identifier.
See chapter 6.2 and chapter 4.3.