7.2.3 ADJUSTING FLUIDIZATION (60 L TANK WITHOUT VIBRATOR TABLE)

WARNING
Dust formation!
Risk of poisoning if inhaled.
Danger due to escaping dust, contamination of the device and device components.
The powder tank may only be fi lled to the halfway mark, because fl uidizing increases
the volume of powder.
1
P_02647
ORDER NUMBER DOC 2354920
Procedure:
1. Open the lid and fi ll the powder tank (1) halfway
2. Switch on the control unit.
3. Set the "Vibrator motor controller" parameter, on
4. Actuate the trigger of the spray gun for a short time
2
5. Adjust the fl uid air at the throttle (2) until fl uidization
6. Close the powder tank 1 and check whether the
Note:
with powder.
the control unit, to "ON" to permanently activate
the fl uid air (see the EPG-Sprint XE control unit
operating manual).
and release it.
is recognizable.
Note:
– The amount of fl uid air depends on the
characteristics of the powder.
Avoid a build up of powder dust (too much fl uid
air) in the powder tank!
exhaust air hose is leading in the direction of the
ventilation system of the powder coating booth.
– We recommend using a vibrator table when
working with powders that are diffi cult to feed
(see Chapter 12.13).