7   Operation
7.2.3   Adjusting fluidization (60 L tank without vibrator table)
WARNING
Dust formation!
Risk of poisoning if inhaled.
Danger due to escaping dust, contamination of the device and device components.
4 The powder tank may only be filled to the halfway mark, because fluidizing increases
the volume of powder.
1
P_02647
1. Open the lid and fill the powder tank (1) halfway with powder.
2. Switch on the control unit.
3. Set the [Vibrator motor controller] parameter, on the control unit, to [ON] to
permanently activate the fluid air (see the EPG-Sprint XE control unit operating
manual).
4. Actuate the trigger lever of the gun for a short time and release it.
5. Adjust the fluid air at the throttle (2) until fluidization is recognizable. NOTICE! The
amount of fluid air depends on the characteristics of the powder. Avoid a build up of
powder dust (too much fluid air) in the powder tank!
6. Close the powder tank (1) and check whether the exhaust air hose is leading in the
direction of the exhaust system of the powder coating booth.
Info
We recommend using a vibrator table when working with powders that are difficult to
feed (see chapter Conversion sets [8 59]).