8.4
SIP
SIP stands for sterilisation in place, in which the pump is sterilised with
superheated steam. For steam sterilization or sanitization, minimum
temperatures of 121 ° C (250 ° F) must be applied to all wetted surfaces. The
maximum permissible temperatures can be obtained from the section technical
data.
The pump must not be in operation during steam sterilisation. A cool-down period
of at least one hour is required after the SIP process.
8.5
Manual exterior cleaning
–
–
–
–
–
–
–
BA.10A.ADY.001.GB_1
20.07.2018
Notice
Danger due to cleaning agents.
► Follow the manufacturer's instructions when using cleaning agents.
► Wear safety glasses and gloves.
► Dispose of cleaning agent properly.
► Do not use a high-pressure water jet to clean the pumps.
Regular manual external cleaning of the pump unit facilitates proper
operation.
Always check the impermeability of the motor (terminal box, condensation
water holes) before each cleaning.
Clean the outside of the pump with a soft cloth or brush and use warm water if
necessary.
When using a cleaning agent, make sure that it does not attack the surface of
the pump unit.
Remove dust and debris that may clog the fan and cooling fins of the engine.
Dry cleaning is preferable to wet cleaning.
The cleaning intervals depend on the degree of contamination.
Cleaning
SIP
45