Wexiodisk WD-90 DUO Installation And User Manual page 90

Combination dishwasher
Hide thumbs Also See for WD-90 DUO:
Table of Contents

Advertisement

Operating instructions
ALARM MESSAGE
(0)
PLATFORM ERROR
(63) POWER SUPPLY
FAILURE
CHECK THE
EMERGENCY SWITCH
(98) HARDWARE ERROR
POWER ON FUNCTION
DEFECT
CALL SERVICE
(61)
EMERGENCY STOP
ACTIVATED
PRESS RESET
(3)
NOMINAL VALUES
CORRUPTED IN MEMORY
CALL SERVICE
(99)
THE MACHINE TYPE
HAS BEEN CHANGED
VERIFY THIS
(2)
INPUT FAILURE ON
DIGITAL INPUTS
CALL SERVICE
(100)
NOMINAL VALUES
RESTORED FROM UI
(4) COMMUNICATION ERR
BETWEEN CPU BOARD
AND I/O BOARD1
CALL SERVICE
(7) COMMUNICATION ERR
BETWEEN CPU BOARD
AND U/I BOARD
CALL SERVICE
(66) SENSOR ERROR
CLEAN AND CHECK
FUNCTION FOR
LEVEL SENSORS
(9)
OVERLOAD PUMPS
ACTIVATED
CALL SERVICE
(10) HACCP ALARM
PUMP FUNCTIONALITY
DEFECT
PRESS RESET
(11) HACCP ALARM
PUMP DEFECT
MACHINE LOCKED
CALL SERVICE
WD-90 DUO
ACTION
Switch off the machine and restart it.
Switch off the machine and restart it.
Switch off the machine and restart it.
Reset the emergency stop by turning it in the direction of the arrows. Reset with
the reset button on the machine.
Contact service personnel!
Contact service personnel!
Contact service personnel!
Reset with the reset button on the machine.
Restart the machine!
Restart the machine!
Clean the level sensors in the wash tank. Reset the alarm by pressing the reset
button.
Contact service personnel!
Reset the alarm by pressing the reset button.
Contact service personnel!
86
Rev. 2.0 (202204)