Operating instructions
Checking and cleaning of initial rinse pipes, final rinse pipes,
cold water jet and draining nozzles
Initial rinse pipes, final rinse pipes and nozzles are checked and cleaned as need-
ed when cleaning the dishwasher in general.
4
2
1
1
The machine's wash compartment with wash arms and cold water jets
1.
Initial rinse pipes, potwash
2.
Initial rinse pipes, normal wash
3.
Final rinse pipes, final rinse
4.
Standard machine: cold water jet
Machine with condensing unit: drain connection
5.
Hood lifting cylinder
Check:
initial rinse pipes, final rinse pipes and jets are not dirty
there is no detritus clogging the wash nozzles on the initial rinse pipes or in
the jets on the final rinse pipes
catches for the initial rinse pipes for normal wash (2) and potwash (1) are
properly engaged
The initial rinse pipes, final rinse pipes and jets are not damaged (if they
are damaged, contact the service company).
Cleaning proceeds as follows:
1.
Rinse the outside of the initial rinse pipes and cold water jets with water.
2.
Open the catches for the initial rinse pipes for normal wash (2) and potwash
(1).
3.
Remove the initial rinse pipes and rinse them out on the inside with water.
4.
Check there is no detritus clogging the wash nozzles or inside the spool
pipes. Remove any detritus.
5.
Refit the spool pipes in their correct position and close the catches around
the pipes.