Power Connections

ATTENTION:
Power input
The IPL EXP RIO8 requires PoE+ power over Ethernet input of at least 48 VDC. The
Extron PI 140 Power Injector and the IPCP Pro 360Q xi can provide appropriate PoE+
output to power the IPL EXP RIO8.
NOTE: The IPCP Pro 360Q xi offers Power over Ethernet+ (PoE+) output on
AV LAN ports 2 and 3. These RJ-45 connectors, labeled "PoE+ Out," can output
a maximum of 30 watts per port. It can be used to power the IPL EXP expansion
interface.
The rest of the IPL EXP I/O Series expansion interfaces (IPL EXP 200, IPL EXP S5,
IPL EXP S2) accept power over Ethernet (PoE) or PoE+ through the LAN port in
addition to network communication.
For all models, see
page 18 for cabling details.
Always use a power supply supplied or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the unit.
Utilisez toujours une source d'alimentation fournie par Extron ou recommandée.
L'utilisation d'une source d'alimentation non autorisée annule toute certification
de conformité réglementaire, et peut endommager la source d'alimentation et
l'unité.
If not provided with a power supply, this product is intended to be supplied by a
UL Listed power source marked "Class 2" or "LPS" and rated output
48 VDC (PoE), minimum 0.35 A or 56 VDC (PoE), minimum 0.8 A.
Si le produit n'est pas fourni avec une source d'alimentation, il doit être alimenté
par une source d'alimentation certifiée UL de classe 2 ou LPS, avec une tension
nominale 48 VDC (PoE) et 0,35 A minimum ou 56 VDC (PoE) et 0,8 A minimum.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une
utilisation dans les espaces d'aération ou dans les cavités murales.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être conforme aux dispositions applicables
du Code américain de l'électricité (National Electrical Code) ANSI/NFPA 70,
article 725, et du Code canadien de l'électricité, partie 1, section 16. La source
d'alimentation ne devra pas être fixée de façon permanente à la structure de
bâtiment ou à d'autres structures similaires.
LAN/PoE and LAN/PoE+ (Ethernet) connectors and LEDs
IPL EXP I/O Series • Hardware Features and Installation
on