IPL EXP I/O Series Expansion Interface Reset Mode Summary
Use This
Activation
Mode to...
Reset IP
To reset all IP settings:
settings and
1.
Press and hold the Reset button until the Reset or Power
port maps
LED blinks once at 3 seconds and twice at 6 seconds.
to factory
2.
Release and press the Reset button momentarily (for
defaults
<1 second) within 1 second*. The LED blinks 3 times in quick
without
succession upon successful reset.
affecting user-
* Nothing happens if the momentary press does not occur
loaded files
within 1 second.
Start over with
To reset the unit to all factory default settings:
configuration
1.
Hold down the Reset button until the Reset or Power LED
and uploading
blinks once at 3 seconds, twice at 6 seconds, and
three times at 9 seconds.
2.
Release and press the Reset button momentarily (for
<1 second) within 1 second*. The Reset or Power LED blinks
4 times in quick succession upon successful reset.
* Nothing happens if the momentary press does not occur
within 1 second.
NOTES:
After performing a Reset All IP Settings or Reset to Factory Defaults reset, either set the IP address again (by
•
using Toolbelt) for use on your network, or turn DHCP on.
•
The factory configured passwords for this device have been set to the device serial number. Passwords are
case sensitive. Performing a Reset to Factory Defaults reset sets the password to extron.
Result
Reset All IP Settings mode:
Turns DHCP off.
•
Sets the IP address back to factory default:
•
•
Sets the subnet back to factory default
•
(255.255.255.0).
Sets the default gateway address to the
•
factory default (0.0.0.0).
Sets domain and host names to factory
•
default.
Sets port mapping back to factory default.
•
Turns events (user-created schedules,
•
macros) off.
Stops any running program.
•
Disables 802.1X authentication.
•
Reset to Factory Defaults mode performs
a complete reset to factory defaults
(except the firmware).
Does everything Reset All IP Settings
•
mode does.
Removes (clears) all user-loaded files
•
(except LinkLicense files) and configurations
from the control processor:
Clears driver-port associations (IR,
•
serial, Ethernet) and port configurations.
Removes button/touchpanel
•
configurations.
Removes user-loaded digital
•
certificates.
Removes schedules, settings, macros.
•
Clears messages in the event logs
•
table.
The unit continues to run the user-loaded
•
firmware.
IPL EXP I/O Series • Hardware Features and Installation