Cabling, Addressing, Features, and Connections

ATTENTION:
Attach cables using the wiring diagrams in this section as a guide.
See either the
Software-based Configuration and Control
the Global Configurator Help File and Toolbelt Help File for information about Global
Configurator and Toolbelt, which you must use to set up the unit.

Power Connections and Circuit Breaker

CAUTION:
ATTENTION :
ATTENTION:
NOTES:
Installation and service must be performed by experienced personnel.
L'installation et l'entretien doivent être effectués par du personnel expérimenté.
SIS Control and Configuration
• Always use the power cord provided with the unit.
• Veillez à toujours utiliser le câble d'alimentation fourni avec l'unité.
• Should you need to use a different power cord, consult Extron Electronics prior to
using the cord.
• Si vous devez utiliser un autre câble d'alimentation, contactez Extron Electronics
avant d'utiliser ce câble.
• Connect the equipment only to a nominal 120 VAC or 240 VAC electrical supply
source.
• Veillez à ne connecter le dispositif qu'à une source d'alimentation nominale de
120 Vca ou 240 Vca.
• Output voltage follows input voltage. Connect the equipment to a supply voltage
suitable for the load equipment.
• La tension de sortie suit la tension d'entrée. Connectez l'équipement à une tension
électrique adaptée à l'équipement de charge.
• The equipment must be connected to an earthed mains socket‑outlet.
• L'équipement doit être connecté à une prise électrique avec mise à la terre.
• Within the United States of America use a power supply cord with conductors that
are a minimum diameter of 17 AWG.
• For international installations, use a power supply cord with conductors that are a
minimum of 1.0 mm
.
2
• Make sure that the device being controlled can support an AC power cycle.
• In case of emergency, disconnect AC power from the power input (appliance inlet)
of the connected equipment.
See the Global Configurator Help File and Global Scripter Help File for details on
Limit and Over conditions and on configuration and programming.
See the
SIS section
later in this guide for SIS control commands.
See
Manual Control (contact closure) ports
manual control port for how to manually select power outputs.
section starting on page 23 or the
section starting on page 36 and
on page 17 for information on the
IPL EXP PDU4H • Hardware Features and Installation
14