Relay ports
The IPL EXP 200 and IPL EXP RIO8 have relay ports, which also provide control for power,
screen or projector lifts, window coverings, and similar items, when trigger events occur.
All relays
are
normally
open.
Rear Panels
1
2 12V24V G
3
4 12V24V G
12 VDC / 24 VDC
or
19W MAX TOTAL
IR/S
RELAYS
5
6 12V24V G
7
8 12V24V G
S G
1 2 C
+V OUT / DIGITAL I/O
RELAYS
To Room
Control
Equipment
Figure 10.
These relay contacts may be used to control any equipment as long as the contact
specifications of a total of 24 V at 1 A are not exceeded for each port. These relays are
normally open by default.
When activated, the open contacts close. They can be set up to operate in one of two
ways:
Latching (brief or indefinite period contact) (press to close, press to open), or
Pulsed (timed cycle) (press to close, timeout to open, with automatic repeat).
In pulse mode the default timeout period (hold time) is ½ second (500 ms). Use Global
Configurator to change the length of the timeout period.
NOTE: The pulse function is absolute: it always sets the relay state to closed, times
out (briefly), then opens the contact. It overrides the previously selected setting (on
state, off state, or toggle).
• Connect devices for contact control.
• Do not exceed a total of 24 V at 1 A for each port.
1
2 3
+V +S -S
Normally
Open
1
To Room
Common
Control
Relay 2
Equipment
Relay 1
Cabling Relay Ports
IPL EXP I/O Series • Hardware Features and Installation
Relays
Closed
2
C
1
2
C
IPL EXP RIO8
Front Panel
IPL
RELAYS
5
1
2
6
3
7
4
8
Relay LEDs
Light when the corresponding relays
are activated (tied to GND, closed).
21