Extron electronics IP Link Pro xi IPL EXP I/O Series User Manual page 24

Control system expansion interfaces
Table of Contents

Advertisement

Rear Panel, IPL EXP RIO8
1
2 12V24V G
3
4 12V24V G
12 VDC / 24 VDC
19W MAX TOTAL
5
6 12V24V G
7
8 12V24V G
+V OUT / DIGITAL I/O
Heat
Shrink
Over
Shield
Wires
G
12V
Sensor, LED,
G
accessory,
24V
or similar item
ECM S10 Tx
Partition closed
Figure 6.
Sensor, LED,
accessory,
or similar item
Extron
OCS 100C
Occupancy
Sensor
Extron
ECM S10 Rx
Receiver does not detect
signal from transmitter.
Wiring the DC Power Output Ports
IPL EXP I/O Series • Hardware Features and Installation
12 VDC and 24 VDC Power Output
Use these ports to power accessories such as occupancy sensors.
Total maximum output is 19 watts, if a PoE+ power supply is used to
power the IPL EXP RIO8. These ports are always on, unless the total
load reaches the overload condition.
Global Con gurator software provides a way to monitor these ports.
• Normal operation mode —The load drawn by connected devices
is 0 - 17 watts.
• Limit mode —The total load on these ports is between 17 and 19
watts.
• Overload mode — The load has reached or exceeded 19 watts.
All power output ports shut off. Power will be restored after you
correct the excessive power draw from the connected devices.
Ground
Wire
Nut
Share the same ground among
I/O connections.
Device 2 digital I/O
with 24 VDC
Device 1 digital I/O
Extron
IPL EXP RIO8
Expansion Interface
Power
12 VDC
Ground
Digital
Input
Ground
Occupancy
Power
Control Output
24 VDC
Ceiling Tile
Hanger Clip
LAN
LAN/PoE
Ceiling
16

Advertisement

Table of Contents
loading