GTZ TX/RX Loopback Connections
See
Figure 1-21
receivers lanes. Use eight SMA female-to-female (F-F) adapters
transmit and receive cables as shown in
•
TX0_P → SMA F-F Adapter → RX0_P
•
TX0_N →
•
TX1_P → SMA F-F Adapter → RX1_P
•
TX1_N → SMA F-F Adapter → RX1_N
•
TX2_P → SMA F-F Adapter → RX2_P
•
TX2_N → SMA F-F Adapter → RX2_N
•
TX3_P → SMA F-F Adapter → RX3_P
•
TX3_N → SMA F-F Adapter → RX3_N
•
TX4_P → SMA F-F Adapter → RX4_P
•
TX4_N → SMA F-F Adapter → RX4_N
•
TX5_P → SMA F-F Adapter → RX5_P
•
TX5_N → SMA F-F Adapter → RX5_N
•
TX6_P → SMA F-F Adapter → RX6_P
•
TX6_N → SMA F-F Adapter → RX6_N
•
TX7_P → SMA F-F Adapter → RX7_P
•
TX7_N → SMA F-F Adapter → RX7_N
To ensure good connectivity, it is recommended that the adapters be secured with a wrench,
Note:
however do not over-tighten the SMA connectors.
VC7222 IBERT Getting Started Guide
UG971 (Vivado Design Suite v2015.1) April 27, 2015
to identify the location of the P and N pins of the GTZ transmitters and
SMA F-F Adapter → RX0_N
www.xilinx.com
Chapter 1: VC7222 IBERT Getting Started Guide
Figure 1-7
and detailed in the following list:
(Figure
1-6) to connect the
Send Feedback
32