FUEL SYSTEM

VENT LINE TERMINATION FITTING

This fitting should be inspected and tested using a Mity
Vac™ to ensure proper venting. Connect the Mity Vac to
the fitting and give it 5 pumps. The gauge should return
to 0 immediately or there is an obstruction.
5
NOTICE
If the vent line fitting is removed from the frame, it must
be replaced. The ears on the clip (arrows) will not hold
properly once it is removed.
9850043 R01 - 2017-2021 RANGER 500 / 570 Service Manual
5.11