Polaris RANGER 500 2017 Service Manual page 93

Hide thumbs Also See for RANGER 500 2017:
Table of Contents

Advertisement

SPN
COMPONENT
Throttle Body Control - Requested
520305
Throttle Angle Not Plausible
520306
ECU ADC Fault - No Load
ECU ADC Fault - Voltage
520307
Accelerator Sensor Sync Fault -
520308
Sensor Diff Exceeds Limit
520309
ECU Fault - ICO
ECU Fault - Hardware Disruption
520311
520331
Knock Sensor Positive Line
Knock Sensor Negative Line
520332
520341
Wastegate Solenoid Driver
520342
Idle Fuel Correction Bank 1
520343
Idle Fuel Correction Bank 2
520344
Adaptive Fuel Correction Bank 1
Internal fault - Chassis Output
520376
Disabled
Non Functional Application SW
520381
Installed
Intercooler Pump Driver Circuit
520496
520498
Stator
520513
Motor Controller Encoder
Motor Controller Temperature
520514
Sensor
Electric Motor Temperature
520515
520516
Motor Controller Temperature
520517
Motor Controller
520518
Motor Controller Contactor
Motor Controller Speed Sensor
520519
520520
BMC CAN Communication
Display Relay
520522
524067
Drive Mode Select Switch
Operator Presence Switch
524070
9850043 R01 - 2017-2021 RANGER 500 / 570 Service Manual
© Copyright Polaris Inc.
FMI
CONDITION
31
Condition Exists
31
Condition Exists
31
Condition Exists
31
Condition Exists
31
Condition Exists
31
Condition Exists
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
15
Data Valid But Above Normal Operating Range - Least Severe Level
15
Data Valid But Above Normal Operating Range - Least Severe Level
17
Data Valid But Below Normal Operating Range - Least Severe Level
15
Data Valid But Above Normal Operating Range - Least Severe Level
17
Data Valid But Below Normal Operating Range - Least Severe Level
31
Condition Exists
31
Condition Exists
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
4
Voltage Below Normal, Or Shorted To Low Source
5
Current Below Normal Or Open Circuit
2
Data Erratic, Intermittent Or Incorrect
31
Condition Exists
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
31
Condition Exists
0
Data Valid But Above Normal Operational Range - Most Severe Level
4
Voltage Below Normal, Or Shorted To Low Source
0
Data Valid But Above Normal Operational Range - Most Severe Level
3
Voltage Above Normal, Or Shorted To High Source
6
Current Above Normal Or Grounded Circuit
12
Bad Intelligent Device Or Component
19
Received Network Data In Error
5
Current Below Normal Or Open Circuit
6
Current Above Normal Or Grounded Circuit
31
Condition Exists
31
Condition Exists
5
Current Below Normal Or Open Circuit
2
Data Erratic, Intermittent Or Incorrect
3
Voltage Above Normal, Or Shorted To High Source
4
Voltage Below Normal, Or Shorted To Low Source
3
Voltage Above Normal, Or Shorted To High Source
GENERAL INFORMATION
CODE
P1530
P1531
P1532
P1533
P1534
P1537
P1327
P1328
P132A
P132B
P0243
P0246
P0245
P116C
P116E
P116F
P0170
P1170
P1618
C1681
P107D
P107C
P107E
P1510
P1511
P1140 / P1368
P1141 / P1369
P1142 / P1165
P1143 / P1166
P1144 / P1167
P1145 / P1168
P1B0D / P1169
P1146 / P116A
P1147 / P1184
P1148 / P1185
P1149 / P1186
P1150 / P1187
P1151 / P1177
P1152 / P1178
P1153 / P116B
P0754
P3038
P153C
P153A
P153B
P251C
1.85