12.6

Network Setting

To set the system network and settings, follow these steps:
1
Tap the Settings button of the main menu and select Network.
2
Select the Control Box, Modbus TCP, Modbus RTU, or Predefined Modbus tab.
Controller: Ethernet network settings for external connections such as the controller or
Modbus can be configured.
Modbus TCP: Additional settings of the Modbus Slave for the Modbus TCP network can
be configured.
Modbus RTU: Additional settings of the Modbus Slave for the Modbus RTU can be
configured.
Predefined Modbus: Modbus setting to be used with some Workcell Items can be
configured.
3
Select the network method and tap the Confirm button.
12.6.1

Modbus TCP/RTU Setting

The Modbus Master of Doosan Robotics can be used for I/O expansion or data exchanges through
connections with other devices.
The Function Codes supported by Doosan Robotics are as follows:
Function Code
*DRL (set_modbus_outputs()) is configured to internally call FC5 and FC6 multiple times.
Note
Up to five Modbus Slave devices can be connected.
Each device can register up to 50 registers.
The total number of registers cannot exceed 100.
1
2
3
4
5
6
Description
Read Coils
Read Discrete Inputs
Read Multiple Holding Registers
Read Input Registers
Write Single Coil
Write Single Holding Register
175