OPERATION
6
Complete all the steps in the setup procedure.
The instrument creates a table of up to 50 pairs of data (level - volume or level - mass). The
reference point for the table is the tank bottom (as given in menu item C.1.2 Tank height.).
INFORMATION!
You can also create customized length and conversion units (free units) in the Conversion setup
procedure.
INFORMATION!
When you create a table, get more conversion data for parts of the tank where there are:
Surfaces with curves.
Sudden changes in the cross section.
This will make volume measurement more accurate.
A plot of points for a volume or mass table
Figure 6-7:
1
Tank with reference points
Tank model with plotted points
2