KROHNE OPTIWAVE 7300 C Handbook page 118

Non-contact radar fmcw level meter
Hide thumbs Also See for OPTIWAVE 7300 C:
Table of Contents

Advertisement

TECHNICAL DATA
10
Vibration resistance
Protection category
Material
Housing
Wetted parts
Process fitting
Gaskets
Feedthrough
Weather protection (option)
Process connections
Thread
Flange
Electrical connections
Terminals output 1 - Non-Ex /
EEx i
Terminals output 1 - EEx d
Terminals output 2 -
Non-Ex/ EEx i/ EEx d
Cable entry
Terminals
Human machine interface (option)
Display
Operating languages
Approvals
ATEX
IECEx
FM or CSA
NEC 500/ CEC
118
IEC 68-2-6 and EN 50178
(10...57 Hz: 0.075 mm / 57...150 Hz:1g)
IP 66/67 equivalent to NEMA 6-6X
Aluminium
Stainless steel (1.4404 / 316L);
®
Hastelloy
C-22 (2.4602)
Stainless steel (1.4404 / 316L);
®
Hastelloy
C-22 (2.4602)
FKM/FPM (-40...+200°C / -40...+390°F);
®
Kalrez
6375 (-20...+200°C / -4...+390°F)
PEI/standard (-40...+200°C / -40...+390°F);
®
Metaglas
(-30...+200°C / -20...+390°F)
Stainless steel (1.4301 / 304)
G 1½; 1½ NPT
DN40...150 (PN40 / PN16);
1½"...8" (150 lb / 300 lb); 10K (40...100A)
14...30 VDC
1
20...36 VDC
1
10...30 VDC
2
M20x1.5; ½ NPT; G ½ (not for FM- and CSA-approved devices)
0.5...1.5 mm²
9 lines, 160 x 160 pixels in 8-step greyscale with 4-button keypad
English, German, French, Italian, Spanish, Portuguese, Japanese,
Chinese (Mandarin) and Russian
ATEX II 1, 1/2, 2 G/D EEx ia IIC T6...T3 IP 6x;
ATEX II 1/2, 2 G/D EEx d [ia] IIC T6...T3 IP 6x;
ATEX II 3 G EEx d [ia] IIC T6...T3
Ex iaD 21 T 65...T 90 IP 6X; Ex ia IIC T6...T4 IP 66
Cl. I, Div. 1, Gr. ABCD (IS);
Cl. I, Div. 1, Gr. ABCD (FM only ) (XP);
Cl. I, Div. 2, Gr. ABCD (XP/NI);
Cl. II, Div . 1, Gr. EFG; Cl. III (FM only ) (XP);
Cl. II Div. 1, Gr. EFG; Cl. III (IS);
Cl. II/III, Div. 2, Gr. FG (XP/NI)
www.krohne.com
OPTIWAVE 7300 C
01/2008 • 4000172401 - HB OPTIWAVE 7300 R03 en

Advertisement

Table of Contents
loading

Table of Contents