OPTIWAVE 7300 C
NEC 505/ CEC
NEPSI
WHG
Other approvals
Options and Accessories
Options
Accessories
min./max. value for an output of 22 mA at the terminal
1
min./max. value for an output of 22 mA at the terminal (additional power supply needed - output only)
2
if the ambient temperature is not in these limits, the display switches off
3
supplied with NPTF ¼ connection
4
for long antenna versions only
5
01/2008 • 4000172401 - HB OPTIWAVE 7300 R03 en
Cl. I, Zone 0 AEx ia Gr. IIC (CSA: Ex ia) (IS);
Cl. I, Zone 1 AEx d [ia] Gr. IIC (XP);
Cl. I, Zone 2, AEx nA [ia], Gr. IIC (CSA: Ex nA [ia]) (IS)
Ex dia IIC T3...T6; Ex ia IIC T3...T6
In conformity with the German Federal Water Act
Gosstandard; PESO (India)
Integrated LCD display with sun cover
(-20...+60°C / -4...+140°F);
2nd current output;
Antenna flushing system
Weather protection; Antenna extensions