KROHNE OPTIWAVE 7300 C Handbook page 65

Non-contact radar fmcw level meter
Hide thumbs Also See for OPTIWAVE 7300 C:
Table of Contents

Advertisement

OPTIWAVE 7300 C
Menu No.
C5.2.2
C.6
C.6.2
C.6.3
Data dependencies for the 4 mA settings of outputs 1 and 2
Output function
Level
Volume
Mass
Distance
Ullage volume
Ullage mass
Data dependencies for the 20 mA settings of outputs 1 and 2
Output function
Level
Volume
Mass
Distance
Ullage volume
Ullage mass
1
TBO = Tank Bottom Offset (C.1.9). RO = Reference Offset (C1.10).
2
TBO = Tank Bottom Offset (C.1.9). BD = Blocking Distance (C.1.11).
3
TBO = Tank Bottom Offset (C.1.9). RO = Reference Offset (C1.10). BD = Blocking Distance (C.1.11).
4
RO = Reference Offset (C1.10).
01/2008 • 4000172401 - HB OPTIWAVE 7300 R03 en
Function
Function description
supervisor
This changes the supervisor
password. Press the push
buttons up to six times in any
order. This will be the new
password. To confirm the
change, enter the new
password a second time.
reset
To reset the instrument to
default settings, refer to
these menu items.
clear error
Erase the error record in
record
menu item B.2.6. Press ^ to
confirm.
restart
If the instrument is not
functioning properly, this will
restart the device. Press ^ to
confirm.
Minimum value
0 m
0.00 m³
0.00 kg
0 m
0.00 m³
0.00 kg
Minimum value
>4 mA setting for level
>4 mA setting for volume
>4 mA setting for mass
>4 mA setting for distance
>4 mA setting for ullage volume Max value in the volume table
>4 mA setting for ullage mass
<20 mA setting for level
<20 mA setting for volume
<20 mA setting for mass
<20 mA setting for distance
<20 mA setting for ullage
volume
<20 mA setting for ullage mass
Tank height + TBO + RO
Max value in the volume table
Max value in the mass table
Tank height + TBO + RO
Max value in the mass table
www.krohne.com
OPERATION
Selection list
Maximum value
Maximum value
1
3
6
Default
>^
>^
Default
0 m
0 m³
0 kg
0 m
0 m³
0 kg
Default
Tank height +
TBO - BD
2
Max value in
the volume
table
Max value in
the mass table
Tank height +
RO
4
Max value in
the volume
table
Max value in
the mass table
65