7
Care and Maintenance
7.8.7.4
Tensioning the V-belt
Slacken the fastening screws 58/1, 58/3 and 59/1.
Rotate the generator (58/2) until the tension is
correct.
Re-tighten the fastening screws 58/1, 58/3 and
59/1.
Check the tension again.
7.8.7.5
Changing V-belts
Slacken the fastening screws 58/1, 58/3 and 59/1.
Rotate the generator against the direction of
tensioning.
Remove the V-belt and fit on an appropriately
sized new one.
Rotate the generator (58/2) in the direction of
tensioning until the V-belt tension is correct.
Re-tighten the fastening screws 58/1, 58/3 and
59/1.
Check the tension again.
Attention
• If V-belts have been replaced, their tension
must be checked again after approx. 20
operating hours.
88/112
Fig. 58 Tensioning and replacing V-belts
Fig. 59 Tensioning and checking V-belts
Operating Manual 12.9.08 Version 1.0